Duct Vibration Isolator 1-Inch Deflection 50 lb Spring

A light-load spring hanger separates a duct support from the building when its operating load and installed clearances are correctly matched.
  • The spring load class suits lightweight suspended components.
  • Rod clearance accommodates modest suspension misalignment.
Request a Quote Browse Products

Match a light support load to a working spring

The 50 lb, nominal 1-inch-deflection hanger is intended for light suspended duct or terminal support points near vibration sources. Its spring allows vertical movement between the supported service and building attachment. A resilient cup or specified neoprene element interrupts direct metal contact. This addresses vibration through the support path; airborne fan noise requires a separate acoustic assessment.

Why oversizing can reduce isolation

The title identifies a nominal load and deflection selection. The operating load must be matched to a supplied load-deflection curve. A stiffer spring chosen simply for extra capacity can compress too little under a light duct, raising the suspended system's natural frequency and reducing useful isolation at the source frequency. Conversely, an overloaded spring can lose travel or become unstable. Neither the load label nor the free height proves the installed deflection.

ReferenceRequired selection detail
50 lb nominal load classActual reaction at this hanger, including duct, insulation, fittings and supported accessories.
1 inch / 25.4 mm nominal deflectionWorking load range, spring rate, loaded height and available travel.
Open metal housing and coated springRod diameter, spring seat, corrosion protection and access to observe clearance.

Keep the load path free of rigid bridges

Locate the hanger so that its rod remains clear of the housing throughout operating movement. A quoted 30-degree allowance requires the actual assembly drawing and its definition; it must not be assumed to mean 30 degrees in every direction or permission for permanent lateral loading. Rod, nut or washer contact can bypass the spring even when the spring itself is correctly selected.

Coordinate adjacent supports, duct connections and service cables so they do not restrain the isolated section. Install using the approved support sequence and retain access for loaded-height checks. After the full operating load is present, inspect the seat, rod clearance and actual compression. Recheck after adding dampers or other accessories that change the support reaction.

Order and accept the complete support arrangement

Submit support locations, loads, fan operating speeds, required deflection and rod interface. Quote the hanger, resilient elements and hardware scope explicitly; structural anchors and lateral or seismic restraints need their own design. Handover should identify each selected spring and record its loaded condition. No percentage isolation efficiency, seismic qualification or overload allowance is claimed here.