Duct Airflow Measuring Station 900 x 900 mm High-Capacity
- Large sensing grid spans high-volume trunk geometry.
- Measurement assembly remains independent of the regulating damper.
A large sampling frame for a main air trunk
The 900 x 900 mm station spreads pressure pickups across a nominal 0.810 m² section. It can supply measured airflow information for a principal outside-air or return-air duct where a single local velocity reading would poorly describe the whole section. Its large frame accommodates trunk geometry; high-capacity in the product name does not define a maximum flow, measuring range or accuracy.
Total and static pressure are compared at a transducer. The listed 0–10 VDC signal remains pressure-based, so a controller needs the correct pressure scaling and the station's conversion relationship. Larger area raises the volume corresponding to a given average velocity, but does not inherently increase the pressure signal at that velocity.
Specify the trunk and the measuring range together
| Parameter | Listed reference and check |
|---|---|
| Frame format | 900 x 900 mm nominal; establish the sleeve, flange and clear-airway dimensions on drawings. |
| Nominal face area | 0.810 m²; the calculation must use the area definition associated with the calibration. |
| Pickup arrangement | Distributed total/static averaging array. |
| Transducer signal | 0–10 VDC differential-pressure output; match pressure range, electrical supply and BMS scaling. |
| Controls | Separate airflow calculation, monitoring, alarm or fan-control integration. |
Large-area averaging has limits
A broad duct can carry strong asymmetry after an elbow, branch junction or partially closed damper. Multiple pickups improve sampling coverage, but their combined pressure is not a guarantee of correct average flow under every profile. Submit the actual upstream and downstream arrangement for siting review. Where access forces a compromised location, agree a site comparison and correction procedure instead of assuming catalog accuracy.
Very low outside-air duty in a large trunk can leave little measurable differential pressure. Define minimum ventilation and maximum duty as separate points when selecting the transducer. For seasonal density changes, state whether the required result is actual volume or a value referenced to standard conditions; an unexplained temperature correction can make trend comparisons misleading.
Structure, tubing and service
The long sensing members and duct frame need support consistent with their installation drawing. Leave inspection access to both the array and the external transducer. Protect small pressure lines from vibration, crushing and water, and check airtight connections. An outdoor-air application also needs consideration of rain carryover and dirt at the pickup location; the station is not an intake weather separator.
Trend drift should trigger checks of ports, tubing and transmitter zero before control settings are adjusted. After nearby ductwork or damper arrangements change, reassess the flow profile and calibration rather than assuming the original comparison remains valid.
Quotation and handover evidence
Supply duct drawings, flow range, air condition, support requirements and intended controller functions. Define whether the price includes the complete frame, transducer, conditioning section, access panels, wiring and field comparison. Handover should document dimensions, orientation, signal conversion and an independent airflow comparison over the operating range. For ventilation alarms, test the real low-flow and signal-fault response separately. The measuring station is independent of a regulating damper and cannot provide shut-off or balancing action alone.
Planning your Duct Airflow Measuring Station 900 x 900 mm High-Capacity specification?
Send us your dimensions, installation conditions, performance targets and required surface finish.