Double MgO Rock Wool Cleanroom Panel 100 mm Heavy

A deep double-board panel requires a use-specific support and performance specification.
  • Rigid liners isolate the fibrous infill from both skins.
  • Handcrafted format accommodates defined module dimensions.
Request a Quote Browse Products

A deep double-board panel for a defined wall or ceiling duty

The 100 mm double-MgO rock-wool panel has a mineral-board backing beneath each coated metal face, a rock-wool centre and galvanized edge closures. The deep layered section is intended for projects that require this particular construction, with the wall or overhead role established before manufacture.

Different loads act in different orientations

In a wall, the support and attachment design responds to panel height, room-pressure forces, impacts and openings. Overhead, the panel must also carry its own weight across the supported span. Two MgO boards add material and change the section; the word Heavy is not a quantified load capacity or permission to walk on the panel.

Reference cover widths are 980 or 1180 mm, metal skins are selected within 0.4–0.8 mm, and the board layers may be approximately 5 mm each in the specified build-up. The rock-wool reference density is 100–120 kg/m³. Use the actual assembly weight and tested or calculated performance for the chosen supports. A ceiling module length is not the same as an allowable clear span.

Coordinate overhead equipment early

Filter units, lights and access hatches remove material and introduce concentrated loads. Their frames and suspensions need an identified route to the supporting structure; fixing through the lower skin alone is not an adequate default. Where maintenance access above the room is needed, specify a designed walkway or an explicitly qualified walkable ceiling system.

Define joints, head or grid connections and movement allowances before fabrication. Keep the mineral layers enclosed at all cuts. The MgO formulation, adhesive and metal interfaces need documented suitability for humidity and cleaning exposure. Neither two boards nor a mineral core establishes an assembly fire-resistance period.

Quotation, delivery and maintenance

Provide the use orientation, support layout, loads, openings and performance requirements. Quote panels, reinforcement, support interfaces, seals and installation separately. Acceptance should include material identity, dimensions, bond integrity, handling condition and construction-specific structural and fire evidence where required.

Inspect overhead connections and any deflection or joint opening after installation. During service, investigate water leaks and loose or bowed faces before cosmetic repair. Changes to equipment loads or new openings require review of the assembly rather than relying on the original panel thickness.