Constant Air Volume Terminal Box DN305
- 305 mm inlet serves a larger branch than the compact model.
- Sealed double-skin blade combines stiffness with controlled positioning.
Maintain the branch total while controlling downstream distribution
The DN305 CAV terminal regulates a medium supply branch with an averaging probe and motorized damper. The reference 305 mm inlet corresponds approximately to the 12 in size class, while the 437 mm body houses the sensing and regulating assembly. Final connection and access dimensions must come from the selected drawing.
A stable total does not balance every outlet
Where the branch feeds several diffusers, the CAV controller maintains the combined flow within its operating range. It does not hold each outlet at its own target. Closing a downstream balancing damper can divert air toward the other outlets while the total remains unchanged. Complete terminal balancing and record the distribution before accepting the zone.
Adding downstream acoustic treatment changes resistance. Include it in the pressure budget and check both sound transmitted through the duct and sound radiated by the terminal casing. A larger inlet is not evidence of a quiet operating point.
Define the control and construction
| Item | Selection requirement |
|---|---|
| Flow setpoint | Within the calibrated measuring and regulating range. |
| Pressure | Enough for the branch at design duty, with an acceptable upper operating limit. |
| Reference body | 22-gauge galvanized steel, double-skin blade and rubber edge seal. |
| Measurement | Multipoint aluminum pressure probe with correctly matched controller scaling. |
| Controls | Power, command, feedback and fault indications defined for the supplied package. |
The controller cannot recover target flow if upstream pressure is too low or downstream resistance too high. Define an appropriate response to sustained flow deviation and power loss. Do not assume that an electrical actuator includes a spring-return function.
Preserve measurement quality
A compact body still needs the specified inlet approach. Avoid distorted flexible duct or a nearby fitting that invalidates the probe arrangement. Keep the pressure tubes accessible and inspect for leaks, kinks or deposits. Mount the box without twisting the blade supports.
Price the terminal, controls, enclosure, attenuation, installation and commissioning separately. Handover should compare measured branch flow with controller indication, verify downstream quantities and document fault behavior. Check room-pressure relationships independently. After changes to diffusers or ductwork, reassess both the total control and the distribution it serves.
Planning your Constant Air Volume Terminal Box DN305 specification?
Send us your dimensions, installation conditions, performance targets and required surface finish.