Home / Products / Air Ducts & Air Distribution / Constant Air Volume Terminal Box DN150
zhengfeng-CONSTANT-AIR-VOLUME-TERMINAL-BOX-DN150

Constant Air Volume Terminal Box DN150

define flow setpoint, pressure range, inlet geometry, controller calibration and power-loss behavior.
  • Integrated sensing and actuation support constant-volume operation.
  • Compact body suits a single small distribution branch.
Request a Quote Browse Products

Active constant flow for a small supply branch

This DN150 CAV terminal uses a multipoint pressure probe, controller and electric actuator to maintain a selected airflow. The controller compares the inferred flow with its setpoint and moves the damper as duct conditions change. It is an actively regulated terminal, rather than a manually locked blade or a self-powered mechanical regulator.

Constant volume has an operating range

The supply fan must provide enough pressure for the target flow through the terminal and downstream system. Once the damper reaches its open limit, it cannot compensate for insufficient pressure. At very low flow, the pressure signal can fall below the reliable measuring range. Select both the setpoint and available pressure against the actual terminal data.

A constant supply quantity does not independently maintain room pressure. Extract flows, transfer openings and door positions also matter. Specify how the terminal operates with these systems, including the intended response to loss of power or control signal; a fail-open or fail-closed position must not be assumed.

Construction references

ItemReference and boundary
InletDN150 designation with approximately 152 mm, or 6 in class, reference connection. Confirm the mating dimensions.
Body length361 mm reference, excluding the required approach and service envelope.
Casing and blade22-gauge galvanized construction reference with double-skin sealed blade.
Probe and bearingsAluminum averaging probe and brass bearing reference construction.

Specify actual sheet thickness, coating, seal material and controller separately. These construction details do not establish a leakage class or chemical compatibility. A rubber edge seal does not make the terminal gas-tight.

Installation and evidence at handover

Provide the straight inlet and orientation required for the supplied probe. Keep sensing tubes correctly connected, supported and accessible. Protect the probe from construction debris and leave room to remove the actuator or controller.

The quotation should identify setpoint, pressure range, measurement accuracy, power, control interface and failure behavior. Commission with an independent flow measurement at the agreed operating conditions, check the controller reading and document its settings. Inspect probe cleanliness, tubing integrity and damper travel during service, especially after duct cleaning or control replacement.

Planning your Constant Air Volume Terminal Box DN150 specification?

Send us your dimensions, installation conditions, performance targets and required surface finish.