Cleanroom Return-Air Riser Wall Panel 980 mm Modular
- Wall cavity preserves usable room area.
- Factory fabrication reduces on-site assembly.
- Lower inlet supports near-floor air collection.
A return path inside a compact wall bay
The 980 mm return-air module places a vertical hollow passage inside a nominal 100 mm partition. A low-level inlet collects room air and carries it toward a duct connection above the room. This arrangement can free floor space in a gowning or buffer room where a projecting return column would obstruct circulation.
The module has no fan and does not set its own airflow. The air-handling system must provide the pressure difference needed to overcome the grille, internal passage, transition and downstream duct losses. Low-level collection can support the room airflow plan, but its effectiveness also depends on supply placement, equipment and door operation.
Choose the opening and channel together
| Reference item | Selection issue |
|---|---|
| 980 mm module width | Fit the wall bay while preserving door clearances and a useful inlet location. |
| 100 mm overall depth | Determine the remaining internal cross-section after skins, framing and closures. |
| 0.6 mm internal keel | Reference frame option; assess the complete section and supported height. |
| Prepainted steel or stainless face | Coordinate finish and cleaning requirements for both exposed and accessible internal surfaces. |
Use the net passage area for channel velocity, and the selected grille data for inlet pressure loss and noise. Gross wall width multiplied by wall depth overstates the usable area. A narrow low inlet may become the restriction even when the riser itself is wide enough.
Keep access and room boundaries intact
Do not hide the grille behind a gowning bench or stored materials. Provide access to the inlet and cavity for inspection, and keep the floor junction from collecting wash water. Seal unintended openings into adjacent wall cavities and make the top transition part of the duct design. This general return path is not a substitute for process containment exhaust.
Quote the panel, grille, balancing provision, top connection, closures, access pieces and installation separately. Supply target airflow, available pressure and the room layout. Acceptance should verify the internal route and seal quality, then measure the installed return flow and room pressure under the specified operating conditions. Record the balanced setting for maintenance.
Planning your Cleanroom Return-Air Riser Wall Panel 980 mm Modular specification?
Send us your dimensions, installation conditions, performance targets and required surface finish.