Your One-Stop Supplier for Cleanroom Equipment and Aseptic Facility EssentialsInternational Project Support
Open mobile navigationClose mobile navigation
Home / Products / Cleanroom Wall & Ceiling Systems / Cleanroom Return-Air Riser Wall Panel 1160 mm Reinforced-Keel
zhengfeng-CLEANROOM-RETURN-AIR-RISER-WALL-PANEL-1160-HEAVY-KEEL

Cleanroom Return-Air Riser Wall Panel 1160 mm Reinforced-Keel

A thicker internal keel does not establish a higher return-air capacity.
  • Thicker frame differentiates this return-wall construction.
  • Continuous cavity carries air above the room.
  • Face-sheet options suit different enclosure finishes.
Request a Quote Browse Products

Reinforced framing addresses the wall, not the fan duty

This 1160 mm return-air module has a nominal 100 mm wall depth and a reference 0.8 mm internal keel. The thicker framing is a construction choice for supporting the metal faces and connections. It does not, by itself, increase the air volume that can pass quietly through the cavity.

The passage must be sized from its clear cross-section, grille and top transition. At a fixed area, increasing flow raises velocity and generally increases aerodynamic losses and noise. Adding framing can also reduce the clear area. Where the required duty exceeds the acceptable pressure or sound level, a deeper channel, additional riser or different duct route may be more useful than a heavier frame.

Specify the structural and air-side details separately

Reference itemRequired definition
1160 mm width and 100 mm depthShow the clear channel after all internal members and closure pieces.
0.8 mm keelIdentify its profile, fastening, support spacing and permitted wall height.
0.4–0.8 mm facesSelect the actual sheet gauge and finish; stainless steel is a separate material option.
Flush partition connectionCoordinate air seals, structural anchorage and the top duct connection.

A serviceable return path

Keep cavity joints closed so the system draws from the intended inlet rather than an adjoining wall void. Support connected ducts without imposing unassessed loads on thin panel skins. Locate balancing and inspection access before closing the wall. Paint or PVDF selection for the room face does not establish compatibility of concealed surfaces with process fumes.

During maintenance, investigate a falling return volume for blocked grilles, changed damper settings or downstream resistance before modifying the panel. Inspect face movement and air leakage if suction or operating conditions change.

For quotation, provide target airflow, available pressure, allowable sound level and the wall and duct layout. Identify whether grilles, dampers, transitions and supports are included. Acceptance should use the selected air-side data and installed measurements, together with structural documentation for the actual section. No maximum airflow follows solely from the reinforced-keel description.

Planning your Cleanroom Return-Air Riser Wall Panel 1160 mm Reinforced-Keel specification?

Send us your dimensions, installation conditions, performance targets and required surface finish.

Talk to Our Team
Inquiry Form

Home

Products

News

About Us

Contact Us