Home / Products / Air Ducts & Air Distribution / Cleanroom Pressure Relief Damper 60 Pa High-Setpoint
zhengfeng-CLEANROOM-PRESSURE-RELIEF-DAMPER-60PA

Cleanroom Pressure Relief Damper 60 Pa High-Setpoint

A passive weighted blade for a nominal 60 Pa pressure target, with room-envelope effects and relief airflow assessed as part of the system design.
  • The higher setpoint differentiates the unit from low-pressure transfer dampers.
  • Adjustable blade weights permit mechanical setting changes during service.
Request a Quote Browse Products

A 60 Pa setting for a deliberately specified pressure difference

The high-setpoint relief selection uses a weighted aluminum airfoil blade to oppose opening until the intended pressure condition develops. The nominal 60 Pa target requires a selected size and pressure/flow curve for the actual relief quantity. Higher setpoint changes the mechanical balance; it does not establish more airflow capacity or a higher cleanroom class.

Check the consequences of a higher room differential

Pressure acts over doors and partitions as well as over the relief blade. A higher differential can increase door-opening force, envelope leakage and the effect of a sudden door opening. The room design must account for those consequences and the receiving space, rather than treating 60 Pa as a universal improvement over a lower cascade.

The passive unit needs the ventilation system to create the pressure difference. It cannot maintain the target when a large open doorway bypasses the transfer route or the supply surplus disappears. Monitoring and any active control remain separate system functions.

Reference build and setting

ItemCatalog reference
Nominal setpoint60 Pa for the defined operating condition.
MechanismBalanced airfoil blade with adjustable weight moment.
BodyExtruded aluminum, mill or powder-coated finish.
Pivots/bushesStainless steel pins and nylon bushes.
Installation optionsWall/grille or duct-frame arrangement.
Performance evidencePressure versus flow, regulating range and allowable setting method for the supplied assembly.

The complete transfer duct and protective face add resistance. Define whether the 60 Pa requirement is across the blade or between rooms, and place measurement taps accordingly. A regulation tolerance cannot be taken from another manufacturer's similarly weighted design.

Installation and service limits

Install with the intended gravity and pivot orientation, a straight frame and clear blade sweep. Leave access to secure and inspect the weights. Adding extra weight without the manufacturer's permitted adjustment range can overload the mechanism or prevent adequate relief. Check rubbing, deposits and pivot wear before changing a previously commissioned setting.

Quote against the minimum and maximum surplus flow, target differential, transfer-route dimensions, finish and testing requirements. At acceptance, record pressure stability, relief quantity and response through the specified system operating range. Evaluate door operation and room-pressure recovery within the project's commissioning plan. This room ventilation regulator is not an explosion vent, pressure-vessel safety device or certified fire/smoke damper.

Planning your Cleanroom Pressure Relief Damper 60 Pa High-Setpoint specification?

Send us your dimensions, installation conditions, performance targets and required surface finish.

Talk to Our Team