Cleanroom Pressure Relief Damper 30 Pa

A weighted airfoil blade varies its opening on a wall or duct transfer route, with a nominal 30 Pa target defined at specified pressure reference points.
  • The intermediate setting suits a stronger cascade than the 15 Pa option.
  • The welded aluminum frame supports stable pivot alignment.
Request a Quote Browse Products

A mechanical pressure setting on a room transfer route

The 30 Pa relief configuration uses a weighted airfoil blade in a welded extruded-aluminum frame. As differential pressure changes, the blade changes its opening so the available transfer path can pass more or less air. No local motor or power supply is required for that movement.

The 30 Pa target belongs to a specific pair of pressure reference points. It is not an absolute room pressure, and it does not guarantee that every adjacent room remains at the desired differential. A pressure cascade must account for all connected spaces and air paths.

Direct wall opening or concealed duct?

A wall installation has a short transfer route, while an in-duct arrangement may be easier to conceal. Bends, grilles and the duct itself consume pressure as flow increases. A blade set to 30 Pa across its own frame may therefore correspond to a different room-to-room pressure. Establish the complete route and reference taps before setting the weights.

ItemCatalog arrangement
Nominal target30 Pa, commissioned for the defined system condition.
BladeBalanced airfoil with weight adjustment.
FrameWelded extruded aluminum.
Pivots/bearingsStainless steel pivots and nylon bushes.
Mounting optionsThrough-wall grille or duct frame.
FinishWhite powder-coat option.

What regulation can cover

The relief blade can only modulate within its travel and flow capacity. If the ventilation surplus exceeds that capacity, pressure can rise; if supply/extract balance no longer creates surplus, the blade cannot supply missing air. A fixed ±3 Pa band requires actual performance evidence over a stated flow range and installation condition.

A stronger nominal cascade is not inherently a better contamination-control strategy. Select the transfer direction according to the room function and connect it only to a suitable receiving space. A passive regulator also does not replace fire/smoke protection where a barrier requires it.

Service, price and acceptance

Preserve the intended pivot orientation, keep the frame square and leave access to the weights and blade. Inspect for deposits, rubbing and damaged bushes if pressure becomes unstable. Changing weights requires recommissioning, not just a visual return to an approximate position.

The quotation should include size selected for the surplus flow, frame, grille, finish, transfer duct and setting/test scope. Acceptance should establish pressure at the defined room reference points across the intended ventilation range, blade freedom and reproducible response. Record the weight setting and room conditions so later maintenance can distinguish a damper problem from a changed air balance.

Planning your Cleanroom Pressure Relief Damper 30 Pa specification?

Send us your dimensions, installation conditions, performance targets and required surface finish.

Talk to Our Team