Cleanroom HEPA Supply Air Terminal 1220 x 610 mm Ultra-Thin 1200 m³/h
- Two-to-one plan shape suits broad rectangular coverage.
- Fanless ducted construction keeps moving components upstream.
A long filtering face with a single perimeter frame
The 1220 x 610 x 150 mm terminal provides an elongated ducted supply face for a long ceiling bay. The listed construction uses an extruded aluminum frame, steel inlet plate and glass-fibre media with hot-melt pleat spacing. Moving components remain upstream because this module contains no fan. Its nominal 1200 m³/h duty must be coordinated with the available pressure and the selected filter assembly.
What the larger format changes
One long unit may reduce the number of separate housings in a ceiling layout, but it concentrates filter handling and service access into a larger component. Check the replacement route, available lifting space and frame support before fixing the module position. A long pack should be carried by its frame without twisting or touching the pleats.
| Catalog item | Selection interpretation |
|---|---|
| External body | 1220 x 610 x 150 mm; total installation depth and ceiling cut-out require the assembly drawing. |
| Reference volume | 1200 m³/h, subject to the selected terminal's documented duty. |
| Initial resistance | Up to 120 Pa was listed; verify the flow condition and losses covered. |
| Humidity | 80% RH was listed; validate the complete assembly's environmental limits and prevent condensation. Relative humidity alone does not describe a wetted filter. |
| Efficiency evidence | Obtain the required HEPA class and filter-specific report. The previous ≥99.9% at 0.3 µm value is not adequate proof of that classification. |
Distribution across the long axis
A shallow plenum and an inlet at one location may feed the near and far portions differently. Select inlet position, internal distribution arrangement and flow as one assembly. A long external dimension does not prove an even face velocity, and dividing volume by outside frame area does not measure the usable filtering face. Where process protection depends on the discharge pattern, specify the relevant airflow study.
Keep the duct independently supported and the full sealing perimeter aligned. Allow space for flanges, fasteners and service tools, not only the 150 mm body. Define whether maintenance replaces the filter pack or complete module; these alternatives have different access and cost implications.
Moisture, loading and replacement
Check cold surfaces and local dew-point conditions where humid air can enter the ceiling void. A dry-air humidity limit does not authorize condensate or washdown entering the media. Protect the filter during construction and clean only the accessible surfaces by a compatible method. Record differential pressure at known flow to distinguish loading from a ventilation-system change.
After damage or replacement, inspect the frame and seal and perform the agreed installed-filter testing. Neither pressure drop nor a factory particle-efficiency result proves the absence of bypass in the mounted terminal.
Order evidence and commissioning scope
Provide the long-bay drawing, handling constraints, design flow, selected filtration standard/class, inlet arrangement and environmental conditions. The quote should identify filter supply, sealing interface, support hardware, outlet face, test ports, replacement provisions and commissioning. Handover records should include the installed identity, airflow, pressure and agreed leakage results, with distribution mapping where required. Do not assign a cleanroom class, lifetime or fixed change interval from the module size alone.
Planning your Cleanroom HEPA Supply Air Terminal 1220 x 610 mm Ultra-Thin 1200 m³/h specification?
Send us your dimensions, installation conditions, performance targets and required surface finish.