Cleanroom Flexible Air Duct DN100 R-8 Insulated
- Flexible construction accommodates modest connection offsets.
- Outer jacket encloses the insulation layer.
A short flexible connection for a small air terminal
This DN100 insulated flexible duct accommodates a modest offset between a rigid branch and a terminal connection. The proposed construction combines a coated woven-fibreglass air liner, wire helix, insulation blanket and reinforced metallized outer jacket. The helix supports the airway; the jacket encloses the insulation. Neither feature makes a compressed or tightly bent run behave like a straight rigid tube.
Match the actual bore and thermal variant
The reference bore is 4 inches, approximately 102 mm, rather than an exact 100 mm. Select the collar and fastening method around that actual interface. A 7.62 m supply length describes the coil package; it does not mean the entire coil should be installed between two nearby points.
R-8 in the product designation identifies the requested insulation selection. The delivered variant needs its own labelled thermal value and test basis; the US customary R-value scale is different from an SI thermal resistance expressed in m²·K/W. Pressure, temperature, air velocity and fire performance must also be documented for that same construction and diameter. Combining the insulation rating of one construction with the pressure limit of another does not establish a usable duct specification.
A small airway is sensitive to installation
Use a short, extended run with gradual bends and enough clearance for the insulation outside the liner. Longitudinal compression increases internal corrugation, while a sharp bend or narrow support can restrict the bore. Calculate resistance using suitable flexible-duct data rather than transferring a metal-duct friction value.
Secure and seal the liner to the collar using the approved connection system, then restore insulation coverage and jacket continuity. A jacket wrapped around a loose inner core cannot prevent air leakage. Keep the connection accessible for inspection, and replace a torn liner or damaged insulation where repair cannot restore the specified construction.
Cleanroom use and order scope
Suitability depends on the liner materials, cleanliness requirements and position relative to final filtration; the product name alone does not establish particle-shedding or disinfection performance. Quote the installed length, collars, fastening and sealing materials, supports and required thermal variant. Acceptance should verify product identity and ratings, intact materials, correct connections, uncompressed routing and the resulting terminal airflow.