Cleanroom Door Interlock Controller Five-Door Single-Board

A local controller for up to five door channels, integrated with matched field devices, a suitable enclosure and an approved release sequence.
  • Local configuration avoids a dedicated programming workstation.
  • Door-status signalling can be passed to an access-control panel.
  • Emergency-release integration is specified together with the lock power circuit.
Request a Quote Browse Products

Local sequencing for up to five door channels

This single-board controller coordinates door-position signals, release requests and lock outputs in a locally wired cleanroom airlock. It is useful when the required sequence fits within five door channels and a compact control assembly is preferred. The board supplies the logic function; a suitable enclosure, DC power supply, locks, sensors and operator stations complete the installation.

For a replacement, the number of existing doors is only the starting point. Match the old operating sequence and each electrical interface before retaining field devices. A relay terminal with a familiar label may have a different powered or potential-free contact arrangement on the replacement board.

Write the intended operating sequence first

Identify which doors must exclude one another, what starts a release request and what confirms the door has closed. A door-position contact reports leaf position; it does not necessarily prove that a lock has engaged. Where that distinction matters, specify the required lock feedback and sufficient inputs. A traffic light should have a documented meaning, such as available to request access, rather than being assumed to certify that the door is physically unlocked.

Access control decides whether a credential is accepted. The interlock decides whether the related door may be released at that stage of the sequence. These functions need an agreed interface so a valid card request cannot bypass the intended airlock restriction during normal operation.

Reference configurationSelection boundary
Up to five doorsDefine monitored openings and the sensors or paired locking devices associated with each channel.
12–24 VDC supply familySelect the rated operating voltage for the supplied revision and compatible field devices.
Magnetic-lock or electric-strike interfaceCheck switching capacity, continuous and starting load, suppression and power-loss behaviour.
Status and alarm connectionsState contact type, signal meaning and the receiving access or warning equipment.
Board-only supplyList enclosure, supply, terminals, protective devices and field stations separately.

Coordinate power and emergency release

The power budget must include the controller and the maximum credible combination of energized locks and indicators. Check voltage at the distant devices under load. A larger power supply does not increase the permitted current through a board output, and a dry contact does not provide a power source.

Emergency release and fire-alarm integration must be designed with the actual lock power circuit and required escape arrangements. A board input alone does not establish the behaviour of separately powered locks. Verify the approved outcome during loss of controller power, loss of lock power and emergency activation, including any standby supply. Normal interlock restrictions must not obstruct required emergency egress.

Commission and maintain the complete chain

Test every request and door sensor, a conflicting request, an open door, the alarm output and the defined reset sequence. Record local settings and terminal assignments for future replacement. If a door remains unavailable, investigate its physical closure, sensor indication and active alarm before changing logic. Protect the board from cleaning liquid inside a suitable enclosure. Door sequencing supports segregation; it does not measure room cleanliness or establish pressure recovery without the corresponding environmental system and acceptance evidence.

Planning your Cleanroom Door Interlock Controller Five-Door Single-Board specification?

Send us your dimensions, installation conditions, performance targets and required surface finish.

Talk to Our Team
Inquiry Form