Home / Products / Air Ducts & Air Distribution / Cleanroom Air Distribution Plenum Box 400 mm Diffuser with DN200 Spigot
zhengfeng-CLEANROOM-AIR-DISTRIBUTION-PLENUM-400-DN200

Cleanroom Air Distribution Plenum Box 400 mm Diffuser with DN200 Spigot

specify accessible adjustment, pressure tubing, exact measurement calibration and lining details.
  • Medium square casing fits a wider ceiling face.
  • Cord-operated options keep adjustment accessible.
Request a Quote Browse Products

Balance a ceiling outlet from an accessible position

The 400 mm diffuser plenum connects a DN200 side branch to a room-side air outlet. Its optional damper cords and pressure tube allow balancing access to be brought down to the diffuser opening, useful where the ceiling void will be difficult to reach after fit-out. These accessories must be included explicitly in the selected assembly.

The measuring connection needs its own calibration

A pressure tap samples a particular location in the plenum. Converting that reading to airflow requires the characteristic or coefficient for the exact box, diffuser face and measurement arrangement. Swapping the face while retaining the old coefficient can give a plausible reading for the wrong flow.

Keep tubing free from kinks, leaks and trapped debris, and identify the adjustment cords and measuring connection for maintenance staff. Manual cords move the damper; they do not provide automatic flow regulation or a position signal to a building controller. Complete final measurements with the face installed when that is the specified method.

Reference dimensions and optional construction

ItemReference or decision
Nominal diffuser400 mm, with face and fixing interface matched to the plenum.
Casing372 × 372 mm and 295 mm high reference envelope.
Side connection198 mm outside spigot reference for DN200 nominal duct.
Supply arrangementGalvanized casing and an internal air-equalising element.
OptionsDamper, pressure tap, accessible adjustment and selected acoustic lining.

Internal acoustic treatment changes the air-contact surfaces and available passage. Specify its retention, cleaning suitability and performance with the complete outlet. Acoustic lining does not automatically provide the external vapor seal needed to prevent condensation.

Access should survive installation

Support the box independently as designed, seal its connections and arrange the inlet without crushing flexible duct. Leave the face removable and keep cords and tubing accessible without letting them obstruct the discharge. Inspect the equalising element and liner during service.

The quotation should state duty, sound criterion, matched face, measurement characteristic, accessories, insulation and suspension. Handover should record measured flow and final adjustment, demonstrate access and verify the room distribution. A convenient measuring tube does not replace the initial selection of the correct diffuser and plenum.

Planning your Cleanroom Air Distribution Plenum Box 400 mm Diffuser with DN200 Spigot specification?

Send us your dimensions, installation conditions, performance targets and required surface finish.

Talk to Our Team