Home / Products / Cleanroom Flooring / Cement-Filled Steel Raised Access Floor 1500 lb
zhengfeng-CEMENT-FILLED-STEEL-RAISED-ACCESS-FLOOR-ST15

Cement-Filled Steel Raised Access Floor 1500 lb

A filled steel shell and matched understructure form a serviceable technical floor assembly.
  • 24 inch welded steel panel
  • Cementitious internal core
  • Design duty requires complete-system evidence
Request a Quote Browse Products

A filled steel panel on a matched stringer system

This configuration uses a welded steel shell with internal cementitious fill and a 4 ft bolted-stringer arrangement. The shell, fill, pedestals and stringers work together to carry loads while retaining access to underfloor services. An epoxy-painted finish protects the steel during its intended service; damaged coating and exposed cut edges still require attention.

The reference module is 24 × 24 in, or 609.6 × 609.6 mm, with a maximum bare-panel depth around 1⅝ in (41.3 mm). It is not interchangeable with a 600 mm module. Verify the panel seat, edge geometry and locking details when extending an existing floor.

Interpret the 1500 lb selection correctly

A 1,500 lb design-duty requirement needs a test report for the exact supplied panel and understructure, including load contact area, location and allowable permanent deformation. The product designation does not establish that capacity by itself. An ultimate failure load is a separate test result and must not be used as an operating allowance.

Repeated rolling also needs its own evidence. Wheel diameter, width, material, load and number of passes determine the test condition; a stationary point-load figure cannot be applied to a moving trolley. Evaluate the transport route through thresholds, turns and service openings, not just the open floor field.

Install for the final equipment plan

Set pedestal height and stringer connections from the selected system drawing. Prepare and anchor the bases as required for the supporting slab. Plan cut-outs before installation because removing shell or fill changes local load paths. Additional supports may be needed beneath cut or perimeter panels.

Choose a compatible top finish for wear and any ESD duty. A painted steel body is not automatically a qualified conductive walking surface. Keep access panels reachable and avoid removing loaded modules or components needed to support neighboring equipment.

Quotation and handover

Separate panel supply, finish, understructure, openings, ramps, grounding and installation in the price. Acceptance should check seating, level, fastening, protected openings and reports for the specified static and rolling duties. Record permitted equipment routes and retain matching spare modules. Inspect rocking, cracks and coating damage during service access before returning panels to use.

Planning your Cement-Filled Steel Raised Access Floor 1500 lb specification?

Send us your dimensions, installation conditions, performance targets and required surface finish.

Talk to Our Team