Home / Products / Air Ducts & Air Distribution / Backdraft Damper Horizontal-Mount Vertical-Upflow
zhengfeng-BACKDRAFT-DAMPER-HORIZONTAL-UPFLOW

Backdraft Damper Horizontal-Mount Vertical-Upflow

A horizontally mounted blade assembly opens with upward exhaust pressure and returns by gravity, with its spring setting matched to the duty.
  • Opening assistance helps the blades respond to a small forward pressure.
  • A simple mechanical arrangement avoids an electrical control connection.
Request a Quote Browse Products

Passive closure in a vertical upward air path

This backdraft damper is installed with its frame horizontal so exhaust air travels vertically upward. Forward differential pressure lifts lightweight aluminum blades; the selected spring arrangement assists opening, while gravity returns the blades toward their seats when forward flow falls. It is intended for an upward exhaust connection, such as the duct beneath a roof fan.

Opening assistance must match orientation

A spring-assisted upflow damper is not interchangeable with a vertical wall damper. Turning it onto its side changes the balance between spring force, blade weight and pressure. Follow the orientation and direction marks for the actual assembly and keep the frame level and square so blades move freely.

ItemCatalog arrangement
Mounting planeHorizontal.
Forward flowVertically upward.
Frame/bladesGalvanized steel frame with aluminum blades.
MechanismPressure opening with selected spring assistance; gravity closure.
MountingDuct-insert arrangement sized to the opening.
Required operating dataStart-open pressure, full-flow pressure drop, permitted velocity and reverse-pressure rating for the supplied size.

The pressure at which a blade first moves is not the pressure required for full opening or rated flow. Select from the complete pressure-loss curve and the fan's available pressure, including low-speed operation. Excessive opening assistance can work against reliable closure; spring adjustment must follow the supplied procedure.

Roof connection and maintenance

Allow clearance above the blades and between the damper and fan so the full stroke is unobstructed. Screws, screens and duct transitions must remain outside the moving envelope. Protect the assembly from water, ice and debris using the roof termination design; the damper itself is not a weather hood.

Inspect blade seats, pivots and springs for deposits or corrosion. Rattling can indicate unstable low flow, wind interaction, poor alignment or damage rather than a need to add arbitrary weight. Keep the intended mechanism intact and use the specified cleaning and lubrication instructions.

Quotation and functional checks

Specify duct dimensions, frame insertion depth, orientation, forward duty, expected reverse pressure and access. Include the spring configuration, supporting frame and any weather protection as defined items. Acceptance should check free motion, operation at minimum and design flow, automatic return on fan stop, and specified leakage under reverse pressure. Passive backdraft reduction does not establish bubble-tight isolation, pressure-relief control or fire/smoke performance.