Antistatic Epoxy Flooring 1 mm Textured
- Nominal 1 mm resin-formed textured build
- Conductive primer and defined grounding layout
- Footwear contact and cleaning included in evaluation
A resin-formed texture for static-sensitive routes
zhengfeng TEXTURED-10 is a nominal 1 mm epoxy ESD floor arrangement with a textured wearing layer above a grounded conductive primer. A compatible thixotropic additive helps the resin retain its profile after application. There is no separate coarse broadcast bed, making the construction shallower than many aggregate-filled slip-resistant systems.
The intended use is an interior route or support area where a smooth ESD surface does not suit the operating conditions. The modest build requires sound, even supporting concrete. It cannot correct substantial depressions, create drainage falls or absorb movement from an untreated joint.
Coordinate texture with electrical continuity
The peaks and valleys change how footwear contacts the floor. The wearing formulation must therefore be assessed as both an electrical contact surface and a walking finish. A rougher appearance does not prove lower charging or a particular slip rating.
Keep the selected binder, additive dosage and coating schedule consistent. Extra filler or an unplanned additional coat can change the profile and the electrical path. Control the film through the valleys rather than assessing build only at the highest peaks. Use a representative trial area to settle texture, colour and the application method before extending the installation.
Inspect the buried conductive stage
The primer, conductive layer and earthing connections have separate roles. Prepare and repair the substrate first, then install the conductive stage according to the approved layer sequence. Check its continuity and connections at the appropriate stage before covering it, while retaining accessible locations for subsequent tests.
Respect the coating intervals and environmental limits of the actual materials. Applying the wearing layer over an unsuitable primer condition can compromise adhesion or electrical behaviour. Do not replace an electrical connection across a floor boundary with an assumed connection through a decorative cove or adjacent metalwork.
Evaluate the finished working surface
Agree floor resistance tests and acceptance limits within the facility ESD programme. IEC 61340-4-1 provides resistance test methods; quoting that method alone does not establish a compliant product. Apply the specified electrode procedure to the finished texture and record measurement conditions.
Also evaluate the intended footwear and walking behaviour with the installed finish. A floor reading alone does not establish personnel charge control. Traction assessment needs the expected contaminants and footwear as well, particularly if moisture or powder can collect in the textured surface.
Reopening and maintenance
Separate permission for pedestrian access, carts and full chemical exposure. A surface ready for people can still be damaged by loaded wheels. Base the reopening schedule on the actual floor temperature and the selected resin cure instructions.
Use cleaning tools that reach the valleys, remove residue and preserve the texture. Inspect doorways and turning points for polishing or local damage. Repairs must restore the conductive layer arrangement and the contact profile, followed by the relevant electrical checks. Include these obligations, the grounding layout and the approved sample in the purchase and handover documents.
Planning your Antistatic Epoxy Flooring 1 mm Textured specification?
Send us your dimensions, installation conditions, performance targets and required surface finish.