Your One-Stop Supplier for Cleanroom Equipment and Aseptic Facility EssentialsInternational Project Support
Open mobile navigationClose mobile navigation
Home / Products / Air Ducts & Air Distribution / Aluminum Air Duct 900 x 450 mm Heavy-Gauge 1.3 mm
zhengfeng-ALUMINUM-AIR-DUCT-900X450-T13

Aluminum Air Duct 900 x 450 mm Heavy-Gauge 1.3 mm

A larger dry-air trunk uses a coordinated aluminum construction schedule rather than thickness alone to define its duty.
  • Broad trunk opening consolidates several distribution branches.
  • Heavy aluminum gauge provides a more substantial shell.
Request a Quote Browse Products

Build a larger dry-air trunk with a coordinated aluminum structure

The 900 × 450 mm trunk uses nominal 1.3 mm 3003-H14 aluminum sheet with folded seams and transverse flange ends. The larger passage can collect or distribute several branches while keeping metal mass lower than a comparable steel shell. The heavy-gauge description is a relative construction label; it does not establish pressure capacity or permit access loads on the duct.

Design the long faces and joints as a system

At this width, broad panels and the connection between them require particular attention to deformation. Select reinforcement from the duct pressure, unsupported span, joint spacing and aluminum material properties. A steel angle or tie design cannot be substituted directly by an aluminum part of the same dimensions without checking stiffness and connection behaviour.

ReferenceEngineering requirement
900 × 450 mm internal sectionOverall envelope including reinforcement, flanges, supports and insulation.
Nominal 1.3 mm 3003-H14 shellSpecified thickness/tolerance and the pressure construction schedule.
External frames or internal tiesApproved member sizes, spacing, attachments and suitability for positive and negative pressure.
Pittsburgh seams; TDC-style connectorsJoint profile and components compatible with the selected aluminum construction.

Longer modules reduce transverse joints but can be harder to transport and may require more panel reinforcement. Shorter modules add joint and sealing work. Branch takeoffs, access doors and large reducers interrupt panel continuity and should be included in the structural layout rather than cut into a completed trunk without review.

Support, seal and inspect the installation

Provide hangers for the actual assembled weight, including fittings, insulation and accessories. Low shell mass does not remove the need to assess building attachments or lateral restraint. Keep lifting forces away from unsupported faces and align connections without forcing the flange corners.

Inspect seam closure and corner seals before insulation conceals them. If condensation is possible, coordinate the vapour barrier and mixed-metal isolation around supports. During operation, investigate panel movement or joint opening instead of treating it as a cosmetic issue. Internal ties and branches must remain accessible to the planned cleaning method.

Quotation and acceptance

Quote a dimensioned trunk layout with reinforcement, elbows, reducers, joints, supports and test scope identified. Supply peak pressure and suction conditions, airflow and environment. Accept against material records, construction details, dimensional checks and the specified leakage test; no fire rating, chemical-service suitability or walking-load capacity is implied.

Planning your Aluminum Air Duct 900 x 450 mm Heavy-Gauge 1.3 mm specification?

Send us your dimensions, installation conditions, performance targets and required surface finish.

Talk to Our Team