Pembekal Satu Henti Anda untuk Peralatan Bilik Bersih dan Kemudahan AseptikSokongan Projek Antarabangsa
Open mobile navigationClose mobile navigation
Laman Utama / Produk / Peralatan Bilik Bersih / High-Containment Weighing Booth 2 ft Single-HEPA
STJH-HIGH-CONTAINMENT-WEIGHING-2FT-SINGLE-HEPA

High-Containment Weighing Booth 2 ft Single-HEPA

A compact ductless weighing enclosure returning single-HEPA-filtered air to the room through a built-in blower.
  • 2 ft compact width
  • Built-in recirculating blower
  • Single HEPA final filter
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

This two-foot system combines a built-in blower and single HEPA filter in a compact recirculating enclosure. It requires no external duct for normal room-return operation, making it suitable for limited bench space and small potent-powder quantities. Application suitability depends on the compound risk and whether single-stage recirculation is acceptable.

Ciri-ciri Utama

Ductless installation

The built-in blower returns filtered air to the room without a remote exhaust connection.

Limited-space containment

The two-foot work zone concentrates capture around one small balance operation.

Integrated mechanical package

Blower and filter remain within the enclosure system for straightforward placement.

Parameter teknikal

Nominal Width2 ft
Pressure ModeNegative work zone
Filter StagesSingle HEPA
BlowerBuilt-in
Exhaust ModeRoom recirculation
External DuctingNot required
Work CapacityOne compact balance
ApplicationSmall potent-powder weighing
MonitoringAirflow indication by configuration
PenyesuaianBoleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi.

Applications

For small potent-powder weighing where bench space and duct access are limited. A qualified risk assessment must confirm that single-HEPA room recirculation is appropriate.

Solutions for Your Application

No external exhaust connection is available at the balance location.Use the built-in recirculating configuration only when the material assessment permits room return.
A larger enclosure leaves excessive reach for gram-scale work.Use the two-foot zone to keep the balance and containers close to the capture path.

Pilihan yang boleh didapati

Select work-surface material, sash, airflow monitor, electrical supply and filter service accessories. More demanding compounds may require double filtration or an isolator.

Planning a High-Containment Weighing Booth 2 ft Single-HEPA specification?

Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Berbincang dengan pasukan kami