Pembekal Satu Henti Anda untuk Peralatan Bilik Bersih dan Kemudahan AseptikSokongan Projek Antarabangsa
Open mobile navigationClose mobile navigation
Laman Utama / Produk / Cleanroom Air Filters / Equal-Pressure Filter Clamping Assembly 610 mm Snap-Tab
STJH-FILTER-CLAMP-ASSEMBLY-SNAP610

Equal-Pressure Filter Clamping Assembly 610 mm Snap-Tab

A quick-service tab set for evenly clamping a full-size header filter into a modular holding frame.
  • Replaceable snap tabs
  • 592 mm full-size filter
  • 0.75 in sealing flange
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

This clamping assembly uses replaceable snap tabs around a 610 mm-class frame to press a 592 x 592 mm header filter against a three-quarter-inch sealing flange. Each tab can be serviced independently, avoiding the long linkage used by a crank housing. The simple mechanism is intended for accessible built-up AHU banks where rapid filter replacement and even perimeter contact are more important than contained change-out.

Ciri-ciri Utama

Fast manual engagement

Tabs snap into the loaded position without a separate row crank or threaded clamp.

Distributed perimeter pressure

Multiple retaining points hold the filter header against the gasket around the full face.

Individual component replacement

A damaged tab can be changed without removing the complete frame from the bank.

Parameter teknikal

Frame Class610 x 610 mm
Compatible Filter592 x 592 mm header filter
MechanismReplaceable snap compression tabs
Sealing Flange0.75 in
Tab MaterialCorrosion-resistant metal
Seal MethodHeader compressed against frame gasket
ServiceFront-access manual release
Bank TypeBuilt-up modular AHU wall
Containment FunctionNot a BIBO mechanism
PenyesuaianBoleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi.

Applications

For accessible built-up AHU filter walls in commercial, healthcare and clean-process ventilation systems using full-size header filters.

Solutions for Your Application

Some tabs are left disengaged and the header leaks at one edge.Use a defined engagement sequence and visually confirm every tab position after the filter is seated.
Repeated changes bend a tab and reduce local clamping pressure.Inspect tab spring condition during each service and replace individual worn pieces before installing the new filter.

Pilihan yang boleh didapati

Confirm frame profile, filter header thickness, gasket material, tab count, access direction, corrosion finish and spare-tab quantity.

Planning a Equal-Pressure Filter Clamping Assembly 610 mm Snap-Tab specification?

Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Berbincang dengan pasukan kami
Email Kami WhatsApp WeChat

Laman Utama

Produk

Berita

Tentang Kami

Hubungi Kami