Pembekal Satu Henti Anda untuk Peralatan Bilik Bersih dan Kemudahan AseptikSokongan Projek Antarabangsa
Open mobile navigationClose mobile navigation
Laman Utama / Produk / Cleanroom HVAC Systems / Dry Room Air Handling Unit 600 CFM
STJH-DRY-ROOM-AIR-HANDLING-UNIT-600CFM

Dry Room Air Handling Unit 600 CFM

A true compact 600 CFM desiccant-rotor dry-room unit with dedicated process and reactivation airflow sections.
  • 600 CFM process-air duty
  • Compact desiccant rotor
  • Gas, steam or electric reactivation
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

The smallest documented HCD physical module uses a compact desiccant rotor, process fan and separate reactivation section rather than reducing a larger machine by fan speed alone. It supplies dry process air for small battery-material, pharmaceutical or moisture-sensitive storage rooms.

Ciri-ciri Utama

True small rotor module

Rotor diameter, fan and reactivation hardware are physically sized for the low airflow instead of being oversized components at minimum speed.

Deep moisture removal

Desiccant adsorption supports lower supply-air dew points than cooling-only dehumidification in dry-room service.

Reactivation heat choice

Gas, steam or electric input can regenerate the rotor according to available site utilities.

Parameter teknikal

Nominal Process Air600 CFM
Dehumidification MethodDesiccant rotor
Process FanCompact dedicated fan
Reactivation AirSeparate regeneration stream
Reactivation HeatGas, steam or electric
ConstructionWeather-tight modular casing
ConfigurationDehumidifier or HCD Plus arrangement
FiltrationProcess and reactivation filters as selected
InstallationIndoor or protected outdoor
PenyesuaianDew-point duty, reactivation source and treatment accessories can be configured for the intended application and operating environment.

Applications

Small battery-material rooms, pharmaceutical drying suites, moisture-sensitive component stores and laboratory dry-air zones.

Solutions for Your Application

Cooling-coil dehumidification cannot reach the required low dew point.Use the desiccant rotor and size its reactivation energy for the entering moisture load.
A larger dry-air module cycles or wastes regeneration energy on a small room.Apply the true 600 CFM physical module near its intended process-air range.

Pilihan yang boleh didapati

Reactivation source, pre- and post-filters, precooling, postcooling, heating, bypass dampers, dew-point sensors and controls can be selected.

Planning a Dry Room Air Handling Unit 600 CFM specification?

Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Berbincang dengan pasukan kami
Email Kami WhatsApp WeChat

Laman Utama

Produk

Berita

Tentang Kami

Hubungi Kami