Pembekal Satu Henti Anda untuk Peralatan Bilik Bersih dan Kemudahan AseptikSokongan Projek Antarabangsa
Open mobile navigationClose mobile navigation
Laman Utama / Produk / Peralatan Bilik Bersih / Aseptic Laminar Flow Workstation 6 ft
STJH-ASEPTIC-LAMINAR-WORKSTATION-6FT

Aseptic Laminar Flow Workstation 6 ft

The largest sterility-module width for broad non-hazardous pharmaceutical preparation and grouped syringe work.
  • 70 in large cabinet width
  • 1080 CFM at 90 fpm
  • 67.5 in critical work dimension
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

This six-foot model extends the A dimension to 70 in and the E working dimension to 67.5 in. Average airflow rises to 1080 CFM at 90 fpm to serve the wider stainless work zone, with a published heat load of 1600 BTU/h. It suits broad preparation layouts but requires more electrical, cooling and structural capacity than the smaller modules.

Ciri-ciri Utama

Broad aseptic workspace

The six-foot interior accommodates grouped syringe work, long trays or multiple instruments.

Higher airflow capacity

The 1080 CFM average flow supports the extended HEPA-filtered working width.

Defined utility planning

Published electrical, heat and weight data support planning for the larger module.

Parameter teknikal

Published Dimensions A/B/C70 x 24.25 x 28 in
Published Dimension E67.5 in
Average Airflow1080 CFM at 90 fpm
Final FilterHEPA, 99.99% at 0.3 µm
Work-Zone ConditionISO Class 5
Electrical Supply115 V, 60 Hz, 10.0 A
Heat Load1600 BTU/h
Shipping Weight510 lb
ConstructionWelded steel with stainless work area
PenyesuaianBoleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi.

Applications

For large sterile-component preparation, grouped syringe processes and broad non-hazardous pharmaceutical assembly. Confirm bench support, cooling load and operator zoning before installation.

Solutions for Your Application

Long trays or grouped preparations extend beyond a four-foot work zone.Use the 67.5 in working dimension to keep the complete critical process beneath filtered airflow.
The larger module adds significant weight and heat to the room.Plan support for the 510 lb shipping weight and include the 1600 BTU/h heat load in HVAC calculations.

Pilihan yang boleh didapati

Configure support base, task lighting, utility connections and work-surface accessories. Workflow dividers should be selected only when they do not disrupt the airflow pattern.

Planning a Aseptic Laminar Flow Workstation 6 ft specification?

Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Berbincang dengan pasukan kami
Email Kami WhatsApp WeChat

Laman Utama

Produk

Berita

Tentang Kami

Hubungi Kami