클린룸 장비 및 무균 시설 필수품의 원스톱 공급업체국제 프로젝트 지원
Open mobile navigationClose mobile navigation
/ 제품 / 클린룸 장비 / Cleanroom Personnel Airlock 52 × 72 in Pressurized
STJH-PERSONNEL-AIRLOCK-52X72-PRESSURIZED

Cleanroom Personnel Airlock 52 × 72 in Pressurized

A two-person HEPA-pressurized airlock that purges the chamber between controlled rooms with different pressure levels.
  • Two-person 39.5 x 64 in chamber
  • EC HEPA fan-filter unit
  • Variable pressure adjustment
견적 요청 제품 찾아보기

상품 소개

The deeper 52 x 72 in model provides a 39.5 x 64 x 83 in usable chamber for approximately two occupants. A ceiling-mounted 2 x 4 ft EC fan-filter unit supplies HEPA-filtered air, while low vents discharge the purge flow and a variable control supports pressure balancing. Room-side filter access reduces the need for overhead service entry.

주요 기능

Active chamber purge

Filtered supply air dilutes particles admitted during door opening before the next door is released.

Pressure balancing

Variable blower speed and low return vents support adjustment to the adjoining room cascade.

Room-side filter service

The ceiling FFU can be configured for clean-side filter replacement without entering the plenum.

기술 매개변수

Overall Dimensions52.32 W x 72 D x 107 H in
Usable Chamber39.5 W x 64 D x 83 H in
Approximate OccupancyTwo persons
Supply Module2 x 4 ft EC fan-filter unit
Final FilterRoom-side-replaceable HEPA
Airflow DischargeLow-level chamber vents
Pressure ControlContinuously variable blower speed
Door ControlInterlocked with emergency release
Power208, 230 or 460 V configuration
사용자 정의의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다.

Applications

For biotechnology, pharmaceutical and controlled manufacturing entries where personnel must pass between rooms with different pressure targets. Purge timing and blower setpoint should be commissioned against the actual leakage and adjacent-room airflow.

Solutions for Your Application

A passive vestibule cannot rapidly remove particles introduced with two occupants.Use the EC FFU purge and establish a delay before the clean-side door becomes available.
Filter replacement would normally require disruptive ceiling access.Specify room-side-replaceable HEPA construction and reserve internal service clearance.

사용 가능한 옵션

Available choices include stainless construction, smart pressure control, touchless door activation, access modules, alarms and purge timers. Final voltage and control logic can match the facility system.

Planning a Cleanroom Personnel Airlock 52 × 72 in Pressurized specification?

치수, 설치 조건, 성능 목표 및 필요한 표면 마감을 보내십시오.

우리 팀과 대화하십시오.
저희에게 이메일 whatsapp WeChat

제품

뉴스

회사 소개

문의하기