/ 제품 / 클린룸 장비 / Fan Filter Unit 24 × 48 in Low-Profile
STJH-LOW-PROFILE-FFU-24X48-318MM

Fan Filter Unit 24 × 48 in Low-Profile

The broadest low-profile model in the group, combining a 2 x 4 ft face with a 318 mm cabinet.
  • 600 x 1210 mm full-length face
  • 7.2 ft² active filter area
  • 726 CFM maximum airflow
견적 요청 제품 찾아보기

상품 소개

This full-length low-profile FFU provides 7.2 ft² of active filter area in a 600 x 1210 mm footprint without increasing the cabinet height beyond 318 mm. Its 650 CFM airflow at 90 FPM is close to the listed 726 CFM maximum, so system resistance and speed adjustment require deliberate commissioning. The model is intended for broad ceiling coverage where vertical space is restricted and fewer module joints are preferred.

주요 기능

Broad shallow coverage

The two-by-four-foot format spans a large ceiling zone while keeping the same low cabinet depth as smaller family members.

Fewer ceiling joints

One long module can replace multiple smaller supply points when the structure and airflow plan support the larger footprint.

Defined high-end duty

Published values of 650 CFM at 90 FPM and 726 CFM maximum provide clear boundaries for airflow balancing.

기술 매개변수

Nominal Module Size2 x 4 ft
External Dimensions23.63 x 47.63 x 12.375 in (600 x 1210 x 318 mm)
Active Filter Area7.2 ft²
Maximum Airflow726 CFM
Reference Airflow650 CFM at 90 FPM
Maximum-Airflow Power193 W
Reference Sound Level70 dBA at 90 FPM
Unit Weight50 lb
InstallationFull-perimeter supported 2 x 4 ft ceiling mounting
사용자 정의의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다.

Applications

Suitable for broad electronics, medical-device and general clean-manufacturing ceiling zones where low overhead clearance limits cabinet depth. Lifting access, perimeter support and room acoustic requirements should be reviewed because this is the largest and loudest model in the low-profile trio.

Solutions for Your Application

Multiple compact FFUs create extra joints across a broad clean zone.Use the 1210 mm filter face to cover a longer bay with one shallow module where the ceiling frame supports it.
The larger unit may exceed the acceptable room noise level at the reference duty.Evaluate the published 70 dBA reference value and balance the fan only to the airflow the process actually requires.

사용 가능한 옵션

Confirm the filter grade, voltage, fan-control method, support frame and acoustic target before ordering. Final airflow should be selected against the installed filter and room resistance.