STJH-EXPLOSION-PROOF-FFU-2X4-TOPSIDE

Fan Filter Unit 2 × 4 ft Top-Side Explosion-Proof

The broadest top-side hazardous-location FFU in this group, built around a 2 x 4 ft ULPA face.
  • 2 x 4 ft broad ULPA footprint
  • 120/240 V, 6.8 A, 820 W input
  • Top-side hazardous-location service arrangement
견적 요청 제품 찾아보기

상품 소개

The 2 x 4 ft model provides the largest accepted filter footprint in the top-side hazardous-location family. Its 23.72 x 47.63 x 19.86 in stainless cabinet uses a 120/240 V, 6.8 A, 820 W single-phase electrical package and top-side ULPA service. A non-sparking motor in a cast-iron explosion-proof housing supports the cited NEC Class I/Class II, Division 1 family construction, subject to evaluation of the complete installed configuration.

주요 기능

Maximum classified-zone coverage

The four-foot filter face serves broader hazardous process areas with fewer module boundaries than smaller family sizes.

Defined electrical package

The listed single-phase input provides a concrete basis for power coordination in the large format.

Protected motor enclosure

The non-sparking motor is contained in a cast-iron explosion-proof housing within the cited product family.

기술 매개변수

Nominal Module Size2 x 4 ft
External Dimensions23.72 x 47.63 x 19.86 in
Housing MaterialStainless steel with 304 stainless filter frame
Final FilterULPA
Filter AccessTop side
Electrical Input120/240 V, 6.8 A, 820 W, single phase, 50/60 Hz
Motor ConstructionNon-sparking motor in cast-iron explosion-proof housing
Hazardous-Location Family BasisNEC Class I/Class II, Division 1 construction
Airflow DirectionFiltered positive-pressure supply
사용자 정의의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다.

Applications

Designed for larger classified pharmaceutical, chemical and aerospace clean areas requiring a broad filtered ceiling module. The large unit must be integrated with the site's area classification, ventilation strategy, electrical isolation, structural support and safe service route.

Solutions for Your Application

Several smaller hazardous-location modules would create extra joints and electrical connection points.Use the 2 x 4 ft unit to consolidate filtered coverage where the ceiling and power system support the larger cabinet.
The large motor load and classified wiring requirements can be underestimated.Coordinate the listed 6.8 A, 820 W package with the approved isolator, cable system and complete hazardous-area design.

사용 가능한 옵션

Confirm area classification, 120 or 240 V input, ULPA filter and seal, stainless finish, ceiling support and top-side access. The entire installation must be assessed as one hazardous-location system.