클린룸 장비 및 무균 시설 필수품의 원스톱 공급업체국제 프로젝트 지원
Open mobile navigationClose mobile navigation
/ 제품 / Cleanroom Air Filters / Exhaust HEPA Filter Housing BIBO Containment
STJH-EXHAUST-HEPA-HOUSING-BIBO

Exhaust HEPA Filter Housing BIBO Containment

A stainless safe-change exhaust cabinet that contains the used HEPA within a side-mounted replacement bag.
  • Contained BIBO replacement
  • Welded stainless cabinet
  • Gasket or gel HEPA seal
견적 요청 제품 찾아보기

상품 소개

This containment exhaust housing adds a bag-in/bag-out change system to the fully welded filter cabinet. A PVC bag attaches to the ribbed side ring so the contaminated HEPA can be isolated before it leaves the pressure boundary. Gasket or gel sealing can be selected for the specified filter. The model is intended for hazardous exhaust where a standard open door would expose personnel or the maintenance area during replacement.

주요 기능

Personnel exposure control

The change bag separates the used filter from the service room throughout withdrawal and sealing.

Robust exhaust boundary

Fully welded stainless construction reduces leakage paths and withstands demanding cleaning environments.

Seal-interface choice

Internal hardware can be matched to either a compression-gasket or gel-trough HEPA element.

기술 매개변수

Housing MaterialStainless steel
Cabinet ConstructionFully welded
Filter SealGasket or gel by configuration
Change SystemBag-in/bag-out
AccessSide door with ribbed bagging ring
Primary DutyHazardous exhaust containment
Filter CapacityMatched HEPA cell arrangement
Bag MaterialPVC or application-selected change bag
Test ProvisionsChallenge and pressure ports by selection
사용자 정의의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다.

Applications

For biosafety, pharmaceutical and chemical containment exhaust systems where maintenance personnel must not contact the contaminated filter face.

Solutions for Your Application

The change bag material is incompatible with disinfectants or process chemicals.Select bag film from the actual exposure and confirm its flexibility, seam integrity and storage life before use.
The HEPA seal cannot be verified after a contained replacement.Provide accessible challenge and measurement ports and perform the required installed integrity test before returning the exhaust line to service.

사용 가능한 옵션

Specify stainless grade, filter face and depth, gasket or gel seal, bag material, access handing, prefilter, test ports and duct transitions.

Planning a Exhaust HEPA Filter Housing BIBO Containment specification?

치수, 설치 조건, 성능 목표 및 필요한 표면 마감을 보내십시오.