상품 소개
The sanitary plate heat exchanger transfers heat through a compressed pack of thin corrugated stainless plates. Alternating product and utility channels provide high surface area in a compact frame, while hygienic port geometry, compatible gaskets and accessible plate surfaces support inspection and cleaning.
주요 기능
High-area chevron plate pattern
Gasketed serviceable plate pack
Hygienic clamp connection options
Uniform port-to-channel distribution
Adjustable compression frame
Expandable plate count
Optional double-wall plate arrangement
응용 프로그램 솔루션
Reliable hygienic heat transfer depends on correct plate selection, gasket compatibility, uniform tightening and flow conditions that limit fouling.
Product fouls poorly distributed channelsSelect hygienic distribution areas and plate patterns suited to viscosity and solids loading.
Utility fluid could cross-contaminate productUse a double-wall plate option or monitored pressure strategy where risk assessment requires added separation.
Gaskets deteriorate under chemicals or heatMatch EPDM, NBR or alternative gasket compounds to temperature and cleaning chemistry.
Uneven tightening causes leakageCompress the plate pack uniformly to the specified frame dimension and inspect tie bars during service.
일반적인 응용 프로그램
Purified Water heating and coolingBiopharmaceutical buffer temperature controlFood and beverage pasteurizationCIP solution heat recoveryPersonal-care product processing
기술 매개변수
Plate count, channel gap, port size, frame rating and gasket compound are selected for the required fluids and thermal duty.
| 핵심 재료 | 316L stainless steel heat-transfer plates with selected hygienic elastomer gaskets |
|---|---|
| 패널 두께 | Corrugated heat-transfer plates typically 0.5–0.8 mm |
| 유효 폭 | Plate-pack effective width typically 200–1200 mm |
| 최대 길이 | Complete frame length typically up to 5000 mm depending on plate count |
| 강철 면면 두께 | Frame pressure plates typically 12–50 mm |
| 코어 밀도 | 316L 스테인리스 밀도 대략 8000 kg/m³ |
| 열전도도 (Thermal Conductivity) | 316L plate material approximately 15 W/(m·K) at ambient temperature |
| 표면 마무리 | Formed stainless plate surfaces with smooth hygienic ports and coated or stainless frame |
| 접합 유형 | Gasketed plate channels compressed by tie bars, with sanitary clamp or hygienic threaded ports |
| 사용자 정의 | 의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다. |
사용 가능한 옵션
EPDM or NBR gasketsSingle- or double-wall platesAlternative plate alloysInsulated coverStainless frameVariable plate countClamp or hygienic threaded ports
Planning a Sanitary Plate Heat Exchanger specification?
치수, 설치 조건, 성능 목표 및 필요한 표면 마감을 보내십시오.