STJH-STERILITY-TEST-ISOLATOR-2G-FILTRATION

Sterility Test Isolator 2-Glove Membrane-Filtration

A compact two-glove sterility isolator arranged around membrane-filtration testing of filterable pharmaceutical samples.
  • Two-glove compact chamber
  • Membrane-filtration layout
  • Integrated H2O2 cycle

Produkteinführung

This model keeps the chamber short and dedicates its internal layout to the filtration canister, sample containers and rinse sequence used for membrane-method testing. Integrated hydrogen-peroxide decontamination prepares the closed work zone before the operator begins the two-glove test campaign.

Key Features

Method-specific arrangement

The working positions prioritize filter canister handling rather than the broad sample staging of the batch model.

Closed decontamination cycle

Hydrogen peroxide is distributed through the enclosure before aeration and aseptic release.

Double-filtered air path

Supply and exhaust HEPA stages support the controlled Grade A or ISO 5 work environment.

Technische Parameter

Glove Ports2
Primary Test MethodMembrane filtration
Work-Zone ClassificationEU Grade A / ISO 5
Air VelocityApproximately 0.45 m/s
Supply FiltrationDouble HEPA configuration
Exhaust FiltrationDouble HEPA configuration
DecontaminationIntegrated H2O2 micro-nebulization cycle
OperationManual membrane-test workflow
MonitoringContinuous process and environmental data option
CustomisierungCanister layout, glove spacing, transfer interface and monitoring instruments can be configured for the test method.

Applications

Routine sterility testing of filterable parenterals, ophthalmic products and other liquid samples using the membrane-filtration method.

Solutions for Your Application

A general isolator wastes space and complicates the membrane test sequence.Arrange the compact chamber around filtration, rinsing and media-transfer positions.
Decontamination residues must fall before testing begins.Complete the programmed aeration phase and verify the configured release condition before handling samples.

Verfügbare Optionen

Filtration hardware, transfer hatch, glove system, particle monitoring and sample-rack arrangement can be specified.

Planning a Sterility Test Isolator 2-Glove Membrane-Filtration specification?

Senden Sie uns Ihre Abmessungen, Installationsbedingungen, Leistungsziele und gewünschte Oberflächenveredelung.

Sprechen Sie mit unserem Team
E-Mail uns WhatsApp WeChat

Startseite

Produkte

Neuigkeiten

Über uns

Kontakt