Ihr One-Stop - Lieferant für Reinraumausrüstung und Essentials für aseptische EinrichtungenInternationale Projektunterstützung
Open mobile navigationClose mobile navigation
Startseite / Produkte / Cleanroom Ausrüstung / FFU BMS Gateway Modbus-to-BACnet IP
STJH-FFU-BMS-GATEWAY-BACNET-IP

FFU BMS Gateway Modbus-to-BACnet IP

A protocol gateway exposing Modbus FFU data to BACnet IP building automation networks.
  • Modbus RTU field network
  • BACnet IP upstream protocol
  • Fan status, speed and alarms

Produkteinführung

This gateway translates Modbus RTU field data from FFUs into BACnet IP objects over Ethernet. It makes fan speed, operating status and alarms available to building systems standardized on BACnet. The protocol conversion distinguishes it from the transparent Modbus TCP bridge and the server-oriented OPC UA/MQTT gateway.

Key Features

BACnet object exposure

FFU points become accessible to a BACnet IP supervisor.

Cross-protocol translation

The gateway converts between fan-side Modbus and building-side BACnet.

Facility alarm visibility

Operating alarms can be included in the building interface.

Technische Parameter

Field ProtocolModbus RTU
BMS ProtocolBACnet IP
Upstream ConnectionEthernet
Exposed FunctionsFan status, speed and alarms
Field NetworkRS485-compatible Modbus segment
Object MappingConfigured BACnet points
Command DirectionBMS setpoints to FFU network
InstallationBuilding controls enclosure
AnwendungHospital and commercial BMS integration
CustomisierungVerfügbar je nach beabsichtigter Anwendung und Betriebsumgebung.

Applications

Recommended for hospitals and commercial facilities using BACnet IP as the building-controls standard. Point naming, object instances and command priorities should be coordinated with the BMS.

Solutions for Your Application

A BACnet supervisor cannot interpret native Modbus fan registers.Translate the required FFU points into BACnet IP objects.
Uncoordinated command priorities can override cleanroom settings.Define writable points and BACnet priority behavior before connection.

Verfügbare Optionen

Specify fan register map, BACnet objects, Ethernet settings, enclosure and access control. Confirm which points are monitored and which may be commanded.

Planning a FFU BMS Gateway Modbus-to-BACnet IP specification?

Senden Sie uns Ihre Abmessungen, Installationsbedingungen, Leistungsziele und gewünschte Oberflächenveredelung.

Sprechen Sie mit unserem Team
E-Mail uns WhatsApp WeChat

Startseite

Produkte

Neuigkeiten

Über uns

Kontakt