Startseite / Produkte / Cleanroom HVAC Systems / Chilled-Water Circulation Pump DN50 2.2 kW
STJH-CHILLED-WATER-CIRCULATION-PUMP-DN50-22KW

Chilled-Water Circulation Pump DN50 2.2 kW

A high-head DN50 inline pump with a 2.2 kW three-phase motor, 240-class hydraulic and flow up to approximately 53 m3/h.
  • DN50 high-head hydraulic
  • 2.2 kW three-phase motor
  • Up to approximately 53 m3/h

Produkteinführung

This largest selected DN50 build uses a 2.2 kW three-phase motor and extended 240-class impeller. It supports higher-resistance chilled-water networks or multiple cleanroom coils while keeping the same nominal connection size as the two lower-head models.

Key Features

Greatest selected head

The 240-class hydraulic addresses long branches, multiple coils or greater control-valve resistance.

Larger motor frame

The 2.2 kW drive provides the input required by the extended impeller at higher duty points.

Variable network response

Speed control can reduce head and energy when fewer cleanroom coils call for flow.

Technische Parameter

Connection SizeDN50
Motor Power2.2 kW
Motor SupplyThree phase
Hydraulic Head Class240
Flow RangeUp to approximately 53 m3/h
Maximum PressureSelected to system pressure class
Pump TypeHigh-head inline centrifugal
ControlElectronic variable-speed option
InstallationSupported inline piping
CustomisierungOperating point, sensor logic and connection accessories can be configured for the intended application and operating environment.

Applications

Higher-resistance chilled-water networks, multiple cleanroom AHU coils, process cooling branches and medium central distribution loops.

Solutions for Your Application

The coil network requires more head than the 1.1 kW pump can deliver.Use the 240-class hydraulic only after confirming the design flow and full branch pressure loss.
High available head may cause noise and control-valve erosion at low load.Apply variable-speed differential-pressure control and balance the branches at commissioned flow.

Verfügbare Optionen

Integrated drive, pressure transducer, duty/standby controls, isolation, check valve, flexible connectors and condition monitoring are available.

Planning a Chilled-Water Circulation Pump DN50 2.2 kW specification?

Senden Sie uns Ihre Abmessungen, Installationsbedingungen, Leistungsziele und gewünschte Oberflächenveredelung.

Sprechen Sie mit unserem Team