موردك الموحد لمعدات الغرف النظيفة وأساسيات المرافق العقليةدعم المشاريع الدولية
Open mobile navigationClose mobile navigation
الرئيسية / المنتجات / Containment & Biosafety Equipment / Sterility Test Isolator 4-Glove High-Throughput
STJH-STERILITY-TEST-ISOLATOR-4G-BATCH

Sterility Test Isolator 4-Glove High-Throughput

An extended four-glove isolator for multi-sample sterility-test campaigns, structured loading and recorded process conditions.
  • Approximately 1894 mm work zone
  • Four glove positions
  • Batch data recording
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

The batch model enlarges the work zone to approximately 1894 mm and provides four glove positions for sequential sample handling. It supports structured loading, decontamination, testing and completed-sample staging across one chamber, with PLC controls recording the defined cycle and operating data.

الخصائص الرئيسية

Multiple sample staging

The long chamber keeps prepared, active and completed test units in separate areas during one campaign.

Four-point access

Operators can reach each stage of the extended workflow without moving items back through the chamber.

Recorded cycle history

PLC automation can capture decontamination and operating events for quality-control review.

المعلمات الفنية

Work-Zone DimensionsApproximately 1894 x 898 x 740 mm
Overall DimensionsApproximately 2460 x 1034 x 2413 mm
Glove Ports4
Work-Zone GradeEU Grade A / ISO 5
Supply and ExhaustDouble HEPA-filtered configuration
Decontamination MethodIntegrated H2O2 cycle
Control PlatformPLC
Data FunctionElectronic cycle and batch records
Process CapacityMulti-sample sterility-test campaign
التخصيصChamber length, test equipment, glove positions, transfer route and data interfaces can be adapted to the laboratory workload.

Applications

High-throughput pharmaceutical quality control, batch-release sterility testing and campaigns involving multiple containers or test units.

Solutions for Your Application

Several test units become mixed during a long campaign.Use the extended deck to establish separate loading, test and completed-sample zones.
Manual notes do not capture every isolator cycle event consistently.Use the PLC data record to retain the configured cycle and operating history alongside the laboratory record.

الخيارات المتاحة

Transfer chamber, test instruments, glove spacing, environmental monitors, data interface and internal racks may be selected.

Planning a Sterility Test Isolator 4-Glove High-Throughput specification?

أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

تحدث مع فريقنا
E البريد الإلكتروني لنا WhatsApp WeChat