موردك الموحد لمعدات الغرف النظيفة وأساسيات المرافق العقليةدعم المشاريع الدولية
Open mobile navigationClose mobile navigation
الرئيسية / المنتجات / Containment & Biosafety Equipment / Closed Restricted Access Barrier System 1200 mm Negative-Pressure
STJH-RABS-BARRIER-SYSTEM-1200-NEG

Closed Restricted Access Barrier System 1200 mm Negative-Pressure

A compact negative-pressure closed RABS for sterile work that needs additional operator and environmental containment.
  • Negative-pressure containment
  • 840 mm work zone
  • 190 m³/h optional exhaust
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

This model retains the compact 840 mm work zone of the positive-pressure unit but reverses the pressure scheme for containment-oriented applications. An optional hard-duct connection is documented at 190 m³/h and 27 Pa, providing a defined basis for facility exhaust planning.

الخصائص الرئيسية

Containment pressure direction

Negative pressure limits outward leakage from the closed process enclosure.

Compact transfer arrangement

A dedicated 355 mm-wide pass-through supports material movement without expanding the main zone.

Defined duct duty

The published optional hard-duct value helps engineers assess connection pressure and airflow demand.

المعلمات الفنية

External Dimensions without Base1340 x 820 x 1320 mm
Main Work Zone840 x 610 x 670 mm
Pass-Through Chamber355 x 610 x 670 mm
Pressure SchemeNegative
Barrier TypeClosed rigid glove-port enclosure
Optional Hard-Duct Exhaust190 m³/h at 27 Pa
Process SuitabilitySterile handling requiring containment
Material EntryDedicated side pass-through
Nominal Size Class1.2 m
التخصيصExhaust connection, glove layout and process services can be configured for the containment application.

Applications

Sterile hazardous compounding support, contained sample handling and small aseptic processes that require negative enclosure pressure.

Solutions for Your Application

The process requires sterile handling but outward leakage must also be limited.Select the negative-pressure configuration and maintain transfer through the enclosed pass-through.
The facility needs a known exhaust duty before duct design.Use 190 m³/h at 27 Pa as the documented optional hard-duct operating point for this size.

الخيارات المتاحة

Hard-duct exhaust, glove-port positions, support base and process penetrations can be coordinated with the room and workflow.

Planning a Closed Restricted Access Barrier System 1200 mm Negative-Pressure specification?

أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

تحدث مع فريقنا
E البريد الإلكتروني لنا WhatsApp WeChat