موردك الموحد لمعدات الغرف النظيفة وأساسيات المرافق العقليةدعم المشاريع الدولية
Open mobile navigationClose mobile navigation
الرئيسية / المنتجات / Cleanroom HVAC Systems / Horizontal Air Handling Unit 14000 CFM
STJH-HORIZONTAL-AIR-HANDLING-UNIT-14000CFM

Horizontal Air Handling Unit 14000 CFM

A large 14000 CFM horizontal AHU with a 57 x 78 x 52 inch cabinet for central air treatment in controlled production facilities.
  • 14000 CFM nominal airflow
  • 57 x 78 x 52 inch cabinet
  • Large central-system component face
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

The largest selected horizontal cabinet measures 57 x 78 x 52 inches and provides the component face needed for 14000 CFM. Its extended inline arrangement accommodates high-capacity filters, coils and fan hardware for a central controlled-production system where sufficient plant-room length is available.

الخصائص الرئيسية

Central horizontal duty

The 14000 CFM platform can serve a large production area or several controlled zones through one duct network.

Broad coil and filter area

The 78 inch cabinet width supports the surface area needed to manage high airflow and thermal load.

Linear service layout

Components are arranged along the airflow direction so each section can be accessed from the plant-room aisle.

المعلمات الفنية

Nominal Airflow14000 CFM
Cabinet Dimensions57 x 78 x 52 in
ArrangementLarge horizontal configuration
Casing ConstructionSingle- or double-wall option
Coil OptionsChilled water, hot water, DX or steam
Filter BankLarge flat or angled section
Fan DutySelected for 14000 CFM and system pressure
DrainageSized condensate pan and drain connection
InstallationIndoor plant-room base or structural frame
التخصيصSection length, coil circuiting and fan duty can be configured for the intended application and operating environment.

Applications

Large controlled production floors, pharmaceutical support plants, clean manufacturing centers and central laboratory ventilation systems.

Solutions for Your Application

High airflow through an undersized casing produces excessive coil velocity and fan pressure.Apply the 57 x 78 inch component face and size each filter, coil and fan section to the actual schedule.
A long horizontal cabinet can block plant-room circulation or component removal.Coordinate section length, service doors and full-width extraction paths before fixing adjacent piping and ductwork.

الخيارات المتاحة

Large water or DX coils, single- or double-wall panels, multiple filter stages, fan arrays, attenuators, access lighting and integrated controls can be selected.

Planning a Horizontal Air Handling Unit 14000 CFM specification?

أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

تحدث مع فريقنا
E البريد الإلكتروني لنا WhatsApp WeChat