موردك الموحد لمعدات الغرف النظيفة وأساسيات المرافق العقليةدعم المشاريع الدولية
Open mobile navigationClose mobile navigation
الرئيسية / المنتجات / Cleanroom HVAC Systems / Explosion-Proof Axial Exhaust Fan 315 mm
STJH-EXPLOSION-PROOF-AXIAL-EXHAUST-FAN-315MM

Explosion-Proof Axial Exhaust Fan 315 mm

A compact classified-area axial fan for small solvent and hazardous clean-process exhaust branches.
  • 315 mm aluminum rotor
  • Zone 1 and Zone 2 reference
  • -20 to 60 C operating range
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

This small hazardous-area tube uses a 315 mm aluminum die-cast rotor, galvanized casing and external Ex connection box. The frozen construction references Zone 1 and Zone 2 service with II 2G Ex h IIB+H2 T4 Gb class marking and a -20 to 60 C operating range. Suitability depends on the actual gas group, temperature class, zone and motor controls; the marking must not be generalized to a different hazard.

الخصائص الرئيسية

Compact classified branch

The 315 mm tube fits smaller hazardous exhaust ducts and local process enclosures.

External Ex termination

The connection box is located for compliant field wiring without exposing ordinary components to the classified stream.

Non-sparking rotor arrangement

Aluminum rotor and selected housing details are configured for the documented hazardous-area build.

المعلمات الفنية

Rotor Diameter315 mm
Hazardous ZonesZone 1 and Zone 2
Reference MarkingII 2G Ex h IIB+H2 T4 Gb class
Operating Temperature-20 to 60 C
RotorAluminum die-cast
HousingHot-dip galvanized steel
Electrical ConnectionExternal Ex-rated box
MotorThree-phase hazardous-area construction by selection
Primary DutySmall classified exhaust branch
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

Applications

For small solvent, chemical and hazardous clean-process exhaust branches after the area classification is confirmed.

Solutions for Your Application

The fan marking does not cover the actual gas group or ignition temperature.Match zone, equipment group, gas subgroup and temperature class to the documented site classification before selection.
An ordinary speed controller invalidates the hazardous-area motor arrangement.Use only compatible protection, wiring and converter controls included in the selected certified construction.

الخيارات المتاحة

Confirm zone, gas group, temperature class, airflow, pressure, motor, control method, guards, flange, coating and monitoring.

Planning a Explosion-Proof Axial Exhaust Fan 315 mm specification?

أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

تحدث مع فريقنا
E البريد الإلكتروني لنا WhatsApp WeChat

الرئيسية

المنتجات

الأخبار

من نحن

اتصل بنا