STJH-CLEANROOM-RCU-810H-1000

Cleanroom Recirculation Air Unit 810 mm Hygienic

A tall hygienic recirculation module combining H14 filtration, EC airflow and sensible cooling.
  • 810 mm total height
  • 1000 m³/h nominal recirculation
  • 1.8 kW cooling capacity
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

This 810 mm high cleanroom RCU fits a 1200 x 1200 mm grid and integrates the return grille, H14 filter, EC fan and a 1.8 kW cooling coil. Its 1000 m³/h nominal airflow supports local air recirculation while the coil addresses sensible heat close to the controlled space. The taller hygienic housing is selected where cooling integration matters more than minimizing plenum depth.

الخصائص الرئيسية

Integrated sensible cooling

The 1.8 kW coil removes local heat within the recirculating clean-air module.

Hygienic component stack

Return grille, H14 cell, EC fan and cooling section are organized in one serviceable housing.

Large grid module

The 1200 mm square format serves a broad local recirculation zone.

المعلمات الفنية

Ceiling Grid Size1200 x 1200 mm
Total Height810 mm
Nominal Airflow1000 m³/h
Cooling Capacity1.8 kW
Final FilterH14
Fan DriveEC fan
Return-Air StageIntegrated return grille
Operating ModeLocal recirculation with sensible cooling
InstallationLarge ceiling or technical-plenum module
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

Applications

Designed for pharmaceutical cleanrooms and controlled production suites requiring local filtered recirculation plus sensible cooling. Coil connections, condensate management and airflow balance should be coordinated with the room system.

Solutions for Your Application

Process heat builds up even when particle filtration is adequate.Use the integrated 1.8 kW cooling coil to address local sensible load within the recirculation path.
Separate fan, filter and cooling sections consume excessive ceiling space.Use the combined 810 mm hygienic housing where the plenum can accept its integrated height.

الخيارات المتاحة

Specify coil connections, control interface, filter seal, access side and condensate provisions. Final airflow and cooling duty must match the room load.