STJH-CLEANROOM-DX-AIR-CONDITIONING-73KW

Cleanroom Direct-Expansion Air Conditioning Unit 73 kW

A 72.7 kW gross-cooling cleanroom DX unit using four scroll compressors, two circuits and three EC fans in a 3100 mm cabinet.
  • 72.7 kW gross cooling
  • 6.9 m3/s nominal airflow
  • Four scroll compressors in two circuits
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

This smallest selected DX build combines four scroll compressors in two refrigerant circuits with three 2.9 kW EC fans. The 3100 x 890 x 1980 mm cabinet delivers 6.9 m3/s for medium clean electronics or test suites requiring packaged precision cooling.

الخصائص الرئيسية

Two-circuit DX staging

Four compressors divided between two circuits allow the refrigeration output to respond in steps to changing load.

Three EC supply fans

The fan set delivers the documented air volume with speed-control capability for the distribution system.

Narrow deep cabinet

The 890 mm depth helps preserve aisle space along the long 3100 mm equipment face.

المعلمات الفنية

Gross Cooling Capacity72.7 kW
Nominal Airflow6.9 m3/s
Cabinet Dimensions3100 x 890 x 1980 mm
CompressorsFour scroll compressors
Refrigerant Circuits2
Supply FansThree 2.9 kW EC fans
Cooling MethodDirect expansion
Humidity FunctionsCooling dehumidification with reheat option
Control TypePrecision temperature and fan control
التخصيصAirflow direction, reheat and refrigeration controls can be configured for the intended application and operating environment.

Applications

Medium electronics cleanrooms, precision test suites, controlled technical rooms and manufacturing areas with high sensible heat.

Solutions for Your Application

A comfort air conditioner cannot maintain conditions as process heat changes rapidly.Use staged scroll compressors and EC fan control around the measured precision load.
One refrigeration stage would provide coarse capacity steps at part load.The four-compressor, two-circuit arrangement divides output across several operating combinations.

الخيارات المتاحة

Upflow or downflow discharge, electric reheat, humidifier, filter upgrades, glycol heat rejection, leak detection and communication interfaces are available.