موردك الموحد لمعدات الغرف النظيفة وأساسيات المرافق العقليةدعم المشاريع الدولية
Open mobile navigationClose mobile navigation
الرئيسية / المنتجات / Containment & Biosafety Equipment / Class III Biological Safety Cabinet 4-Glove 1985 mm
STJH-CLASS-III-BIOLOGICAL-SAFETY-CABINET-4G-1985

Class III Biological Safety Cabinet 4-Glove 1985 mm

The widest cabinet in the family, with four glove ports and a 1985 mm work zone for long or shared high-containment processes.
  • 1985 mm work-zone width
  • Four glove ports
  • Two-operator process capacity
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

This four-glove configuration more than doubles the compact model's usable process span while retaining the same 743 mm internal height. The extended chamber accommodates longer instrument trains or a coordinated two-operator procedure behind one continuous Class III barrier.

الخصائص الرئيسية

Extended equipment train

The long stainless deck accommodates linked instruments without crowding the transfer end of the enclosure.

Shared manipulation access

Four glove positions allow two operators to work at separated sections when the procedure permits.

Robust sanitary fabrication

Heavy-gauge welded stainless construction supports repeated cleaning and vapor decontamination routines.

المعلمات الفنية

Work-Zone Dimensions1985 x 559 x 743 mm
Overall Dimensions2417 x 629 x 1940 mm including stand
Glove Ports4 double-groove ports
Cabinet ClassClass III biological safety cabinet
Pressure ModeNegative-pressure sealed barrier
Air FiltrationSingle inlet HEPA and double exhaust HEPA
Interior Material304 or 316L stainless steel
إنهاء السطحPharmaceutical-grade polished finish
Standard TransferStatic interlocked double-door airlock
التخصيصAdditional embeds, transfer hardware, glove positions and service connections can be engineered around the process train.

Applications

Complex BSL-3 or BSL-4 research, two-person virology work and high-risk processes using multiple instruments in a continuous sealed chamber.

Solutions for Your Application

A long instrument sequence cannot fit between two or three glove ports.Distribute the sequence across the 1985 mm deck and use four access positions for each process stage.
Large equipment may complicate material entry and removal.Configure the airlock or a compatible through-wall transfer interface around the largest validated load.

الخيارات المتاحة

Custom pass-throughs, RTP or autoclave embeds, cameras, utility connections, glove choices and exhaust arrangements are available.

Planning a Class III Biological Safety Cabinet 4-Glove 1985 mm specification?

أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

تحدث مع فريقنا
E البريد الإلكتروني لنا WhatsApp WeChat