الرئيسية / المنتجات / Cleanroom Air Filters / Bag-In/Bag-Out HEPA Filter Housing One-High Two-Wide Gasket-Seal
STJH-BIBO-HEPA-HOUSING-GASKET-1H2W

Bag-In/Bag-Out HEPA Filter Housing One-High Two-Wide Gasket-Seal

A two-filter-wide containment section that increases airflow capacity while keeping both cells within one safe-change cabinet.
  • Two full-size HEPA cells
  • 51 in published cabinet width
  • Gasket-seal BIBO access
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

This one-high by two-wide housing accepts two full-size 24 in filters side by side. The published configuration is 30 in high and 51 in wide, with a 26 in cabinet depth for the documented 12 in primary-filter arrangement. Its larger face area reduces the need to stack separate single-cell cabinets, while gasket compression and bagged side access maintain the service approach used in containment systems.

الخصائص الرئيسية

Parallel filter capacity

Two adjacent cells share one housing section for higher airflow at a single-filter-high profile.

Heavy stainless construction

Published 11- or 14-gauge 304L and 316L options support demanding exhaust environments.

Individual contained service

Each cell can be addressed from the bagging side without exposing the contaminated filter face to the room.

المعلمات الفنية

Bank Configuration1 filter high x 2 filters wide
Housing Height30 in
Housing Width51 in
Published Housing Depth26 in for a 12 in primary-filter configuration
Filter FaceTwo nominal 24 in full-size cells
Filter SealCompression gasket
Housing Material11- or 14-gauge 304L or 316L stainless steel
Change SystemSide-access bag-in/bag-out
Duct ConnectionFlanged rectangular inlet and outlet
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

Applications

For higher-flow biotechnology, pharmaceutical and nuclear-support exhaust lines where two full-size HEPA elements are required across one row.

Solutions for Your Application

One filter in the two-wide row carries more flow because the inlet is offset.Use a properly proportioned transition or plenum and verify comparable resistance across both installed filters.
The 51 in cabinet cannot pass through the plant access route.Check doors, lifts and service corridors before fabrication and use modular field connections if site access requires smaller sections.

الخيارات المتاحة

Confirm filter depth, stainless grade and gauge, gasket location, airflow, transition geometry, test sections, bag material and lifting provisions.

Planning a Bag-In/Bag-Out HEPA Filter Housing One-High Two-Wide Gasket-Seal specification?

أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.