الرئيسية / المنتجات / Cleanroom Air Filters / Antistatic HEPA Filter for Hazardous Areas 610 × 610 × 292 mm H13 V-Bank ATEX-Supported
STJH-ATEX-HEPA-H13-610X610X292

Antistatic HEPA Filter for Hazardous Areas 610 × 610 × 292 mm H13 V-Bank ATEX-Supported

A conductive full-size H13 V-bank for high-volume particulate control in correctly classified hazardous areas.
  • 4000 m3/h rated airflow
  • H13 final filtration
  • Conductive 292 mm V-bank
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

This 292 mm-deep H13 model places V-shaped pleated cells in a stainless enclosure with a dirty-side gasket and conductive construction. Its 4000 m3/h duty is the highest airflow in this ATEX-supported HEPA trio, making it the practical choice when an explosive-atmosphere AHU needs full-module capacity without stepping up to H14 media. The filter must be bonded to the specified earth path and used only in a zone covered by the selected construction.

الخصائص الرئيسية

High-volume H13 duty

The full-size V-bank handles 4000 m3/h at a 290 Pa clean pressure drop, reducing the number of cells needed in a high-flow bank.

Conductive metal assembly

Interconnected metallic components provide the physical route required for controlled electrostatic charge dissipation when correctly earthed.

Wet-air tolerance

The published construction tolerates 100% relative humidity and process-air temperatures up to 120 C within its complete material limits.

المعلمات الفنية

Dimensions610 x 610 x 292 mm
Efficiency ClassH13
Rated Airflow4000 m3/h
Initial Pressure Drop290 Pa ±10%
Frame ConstructionConductive stainless steel catalogue frame
Seal PositionDirty-side compression gasket
Maximum Operating Temperature120 C
Moisture Resistance100% RH
Recommended Final Pressure Drop600 Pa
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

Applications

Specified for high-flow supply, recirculation or process-air banks in food, chemical and pharmaceutical facilities after the hazardous zone, gas or dust group, grounding method and housing materials have been assessed. H13 efficiency addresses particles; it does not replace explosion-risk controls elsewhere in the system.

Solutions for Your Application

The hazardous-area filter bank cannot deliver design airflow without excessive fan load.Use the 4000 m3/h H13 full module where the required particle grade permits it, then verify the 290 Pa starting resistance against the available fan pressure.
A conductive filter may be installed without a dependable earth connection.Provide a verified bonding path from the metal frame through the housing and inspect that connection whenever the filter is replaced.

الخيارات المتاحة

Confirm zone and explosion group, airflow direction, gasket side, earthing interface, mating rack dimensions and any required handling feature before release.