STJH-WATER-COOLED-CONDENSING-UNIT-36000BTUH

Water-Cooled Condensing Unit 36000 Btu/h

A three-ton-class 36000 Btu/h R32 condensing unit with larger compressor, plate heat exchanger and fluid connections.
  • 36000 Btu/h class
  • Three-ton indoor format
  • Enlarged brazed-plate condenser
Запрос котировки Просмотреть продукты

Введение продукции

The mid-range water-cooled unit increases compressor displacement and brazed-plate condenser size for approximately 36000 Btu/h. Larger refrigerant and water connections support a medium clean-process or comfort DX circuit without an outdoor condenser fan.

Основные характеристики

Medium water-cooled duty

The larger compressor handles a substantial evaporator load while remaining an indoor packaged unit.

No outdoor condenser fan

Heat transfers to condenser water, avoiding outdoor airflow and external coil exposure.

Expanded connection sizes

Larger water and refrigerant interfaces match the increased capacity and circulation requirement.

Технические параметры

Cooling Capacity36000 Btu/h class
Nominal Size3-ton class
RefrigerantR32
CondenserBrazed-plate water-cooled
CompressorMedium packaged compressor
Condenser-Water CircuitField-connected flow and return
Refrigerant CircuitRemote indoor evaporator
Safety InterlocksWater-flow and refrigerant-pressure options
InstallationIndoor equipment space
CustomizationWater connections, protection controls and evaporator interface can be configured for the intended application and operating environment.

Applications

Medium clean-process cooling, controlled storage, indoor comfort DX circuits and pharmaceutical support systems with condenser water.

Solutions for Your Application

The 12000 Btu/h package cannot meet the medium evaporator load.Use the three-ton-class compressor and plate exchanger at the calculated water and refrigerant conditions.
Water-side fouling can reduce condenser heat transfer.Provide clean water quality, a serviceable strainer and isolation for plate-exchanger maintenance.

Доступные варианты

Flow-control valve, water-pressure instrumentation, receiver, service ports, compressor protection, vibration isolation and remote monitoring are selectable.

Planning a Water-Cooled Condensing Unit 36000 Btu/h specification?

Отправьте нам ваши габариты, условия монтажа, целевые показатели производительности и требуемую отделку поверхности.

Поговорите с нашей командой
Электронная почта WhatsApp WeChat

Главная

Продукция

Новости

О нас

Контакты