Ваш универсальный поставщик оборудования для чистых помещений и асептических средствПоддержка международных проектов
Open mobile navigationClose mobile navigation
Главная / Продукция / Cleanroom HVAC Systems / Screw Chiller 783 kW Water-Cooled
STJH-SCREW-COMPRESSOR-CHILLER-783KW

Screw Chiller 783 kW Water-Cooled

A 225-ton-class water-cooled twin-screw chiller delivering approximately 782.5 kW with a 33.7 l/s evaporator flow.
  • Approximately 782.5 kW cooling
  • 33.7 l/s evaporator flow
  • 225-ton physical configuration
Запрос котировки Просмотреть продукты

Введение продукции

The 225-ton configuration increases cooling to approximately 782.5 kW and input to 147.7 kW. Larger evaporator and condenser water hardware distinguish it from the 150-ton frame for medium-to-large clean manufacturing plants.

Основные характеристики

Expanded process capacity

The larger heat exchangers and compressor serve a central loop beyond the compact 563 kW machine.

Twin-screw modulation

Capacity control follows changing utility load while maintaining chilled-water supply conditions.

Larger water-side hardware

The 33.7 l/s evaporator duty requires appropriately sized connections, pumps and strainers.

Технические параметры

Nominal Capacity225 tons / approximately 782.5 kW
Input Power147.7 kW
Evaporator Flow33.7 l/s
Compressor TypeHermetic twin screw
Heat RejectionWater-cooled condenser
EvaporatorShell-and-tube chilled-water circuit
Capacity ControlContinuous or stepped screw modulation
Water-Side AccessoriesFlow switch and isolation options
InstallationIndoor central utility plant
CustomizationWater connections, electrical selection and capacity controls can be configured for the intended application and operating environment.

Applications

Medium-to-large pharmaceutical plants, electronics production, controlled manufacturing and central utility chilled-water systems.

Solutions for Your Application

The plant load is too large for a compact 150-ton chiller but remains below dual-circuit scale.Use the 225-ton configuration at the verified design and part-load operating points.
Existing pumps cannot deliver the larger evaporator flow without excessive pressure loss.Check the 33.7 l/s duty against pump curves, pipe sizing and heat-exchanger pressure drop.

Доступные варианты

Water-box options, electrical starter, sound treatment, pump controls, heat recovery, pressure ratings and plant-network integration can be selected.

Planning a Screw Chiller 783 kW Water-Cooled specification?

Отправьте нам ваши габариты, условия монтажа, целевые показатели производительности и требуемую отделку поверхности.

Поговорите с нашей командой
Электронная почта WhatsApp WeChat