Ваш универсальный поставщик оборудования для чистых помещений и асептических средствПоддержка международных проектов
Open mobile navigationClose mobile navigation
STJH-POSITIVE-PRESSURE-HEPA-SUPPLY-200CFM

Positive-Pressure HEPA Air Supply Unit 200 CFM

A 300 mm cube filtered make-up-air module for small rooms requiring a 200 CFM positive-pressure supply.
  • 300 mm cube cabinet
  • 200 CFM supply duty
  • Adjacent-area make-up air
Запрос котировки Просмотреть продукты

Введение продукции

The 200 CFM model is the smallest fixed positive-pressure module in this family. Its 300 x 300 x 300 mm metal enclosure draws fresh air from an adjacent area and passes it through a HEPA filter before supply to the clean room. This dedicated make-up function differs from mobile recirculating purifiers and suits compact spaces with limited wall area.

Основные характеристики

Minimal enclosure volume

The cube geometry fits small partition openings and equipment-side pressure zones.

Dedicated make-up path

Air is transferred from an adjacent area instead of merely recirculating within the clean room.

Uniform filtered supply

The HEPA stage supports an even clean-air contribution to the room pressure balance.

Технические параметры

External Dimensions300 x 300 x 300 mm
Rated Airflow200 CFM
FiltrationHEPA
Published Cleanliness ClassISO 5
Air SourceFresh air from adjacent area
Primary FunctionPositive-pressure make-up supply
HousingMetal enclosure
InstallationFixed wall or partition interface
Airflow PatternUniform filtered discharge
CustomizationДоступно в зависимости от предполагаемого применения и операционной среды.

Applications

Suitable for small inoculation rooms, IVF support spaces, compact laboratories and localized preparation rooms requiring filtered make-up air. Available adjacent-air volume must exceed the intended supply without destabilizing nearby rooms.

Solutions for Your Application

A compact room has no space for a full-size air-handling module.Use the 300 mm cube housing at the partition and allocate the 200 CFM duty to the room balance.
Recirculation alone cannot create sustained positive pressure.Introduce filtered air from the adjacent area and provide a controlled relief path from the protected room.

Доступные варианты

Confirm HEPA grade, inlet and outlet treatment, electrical supply, fan control and mounting frame. The room relief path should be coordinated with the 200 CFM input.

Planning a Positive-Pressure HEPA Air Supply Unit 200 CFM specification?

Отправьте нам ваши габариты, условия монтажа, целевые показатели производительности и требуемую отделку поверхности.