STJH-FFU-GROUP-PANEL-NIGHT-ALARM

FFU Group Control Panel Filter Alarm and Night Mode

A grouped FFU panel adding filter alarms and reduced-duty night operation.
  • Audible and visible filter alarm
  • Reduced-speed night mode
  • External 24 V controls
Запрос котировки Просмотреть продукты

Введение продукции

This external control panel adds audible and visible filter alarms plus a reduced-speed night mode to basic FFU grouping. The 24 V control basis is intended for continuously operated cleanrooms that can reduce airflow during unoccupied periods but still need clear maintenance indication. It differs from the five-circuit panel through alarm and operating-mode functions.

Основные характеристики

Maintenance indication

Two alarm channels provide both visual and audible notice of filter condition.

Unoccupied setback

Night mode reduces FFU duty without relying on manual fan-by-fan adjustment.

Accessible interface

External mounting keeps status and mode selection outside the clean space.

Технические параметры

Control Voltage24 V
Alarm TypeAudible and visible
Alarm DutyFilter condition indication
Night ModeReduced FFU duty
MountingExternal
Control ScopeGrouped FFUs
Operating PeriodContinuous rooms with unoccupied setback
User InterfaceLocal mode and alarm panel
Connected EquipmentCompatible FFU group system
CustomizationДоступно в зависимости от предполагаемого применения и операционной среды.

Applications

Recommended for cleanrooms that operate continuously but permit lower airflow when unoccupied. Night settings must preserve the required pressure and recovery time.

Solutions for Your Application

Filter condition is missed until airflow visibly declines.Use audible and visible alarm outputs to prompt inspection.
Fans remain at daytime duty through empty periods.Apply reduced-speed night mode within the room's validated operating limits.

Доступные варианты

Define FFU group size, alarm reset, night speed, schedule interface and enclosure location. Confirm pressure retention at the reduced setting.

Planning a FFU Group Control Panel Filter Alarm and Night Mode specification?