STJH-CLEAN-WARD-SUPPLY-CEILING-1659X1659

Clean Ward Supply Ceiling 1659 × 1659 mm

A medium square patient-protection ceiling with greater bedside coverage and three plenum-height choices.
  • 1659 x 1659 mm medium field
  • 2480 m³/h clean supply
  • Three selectable plenum heights
Запрос котировки Просмотреть продукты

Введение продукции

The 1659 mm model expands the protected footprint for isolation or protective-environment rooms with equipment beside the bed. Its cited airflow is 2480 m³/h through an H14-filtered ceiling field. Plenum heights of 300, 450 or 550 mm allow the module to adapt to different ceiling voids and connection arrangements.

Основные характеристики

Wider bedside zone

The medium field covers more of the patient and adjacent care workspace than the compact unit.

Ceiling-void adaptability

Three plenum depths accommodate shallow renovations or deeper new-build service zones.

Terminal clean-air delivery

H14 filtration immediately upstream of the outlet limits downstream contamination paths.

Технические параметры

Outlet Field1659 x 1659 mm
Clean Airflow2480 m³/h
Final Filter ClassH14
Plenum Height300, 450 or 550 mm
Supply PatternLow-turbulence downward flow
CoveragePatient bed and adjacent care zone
MountingIntegrated into ward ceiling
Filter AccessSelected for ceiling and service layout
Typical RoomIsolation or protective-environment room
CustomizationДоступно в зависимости от предполагаемого применения и операционной среды.

Applications

For isolation and protective-environment rooms needing clean air across the bed and a wider bedside care zone. The plenum height is selected around available ceiling space.

Solutions for Your Application

The compact field does not cover infusion stands or close bedside procedures.Use the 1659 mm square field to extend clean supply beyond the mattress footprint.
Existing ceiling services leave only a shallow space for an air plenum.Select the 300, 450 or 550 mm plenum height that fits the coordinated service zone.

Доступные варианты

Choose plenum height, construction material, outlet membrane, filter-access direction, monitoring and service penetrations. Air volume may be adapted to the room design.

Planning a Clean Ward Supply Ceiling 1659 × 1659 mm specification?

Отправьте нам ваши габариты, условия монтажа, целевые показатели производительности и требуемую отделку поверхности.