STJH-CLASS-III-BIOSAFETY-CABINET-3050-DUAL

Class III Biosafety Cabinet 3050 mm Dual-Chamber

A large gas-tight Class III system with two 1525 mm work chambers and a central staged-transfer interface.
  • Two 1525 mm chambers
  • Central pass-through
  • Gas-tight stainless system
Запрос котировки Просмотреть продукты

Введение продукции

Two connected chambers create an approximately 3050 mm process line for separating culture from analysis or other sequential virology stages. The central pass-through moves material between zones without opening either gas-tight chamber to the room.

Основные характеристики

Separated process stages

Culture and analysis can occupy independent chambers within one contained line.

Internal staged transfer

The shared pass-through limits direct movement between the two work zones.

Class III filtration

HEPA supply and double exhaust filtration serve the sealed stainless system.

Технические параметры

Overall LengthApproximately 3050 mm
Work ChambersTwo
Chamber Width1525 mm each
Inter-Chamber TransferShared central pass-through
Cabinet ClassClass III
ConstructionGas-tight stainless steel
Supply FiltrationHEPA
Exhaust FiltrationDouble HEPA
Primary WorkflowSeparated virology stages
CustomizationGlove positions, chamber services and pass-through format can be configured for the staged process.

Applications

Large virology, disease surveillance and contained workflows requiring separate culture and analysis chambers.

Solutions for Your Application

Culture and analysis activities should not share one crowded work zone.Assign each 1525 mm chamber to a distinct stage and transfer through the central interface.
Moving samples between stages could break room containment.Use the internal pass-through without opening either chamber to the laboratory.

Доступные варианты

Glove layout, transfer hardware, internal equipment and service penetrations can be configured per chamber.

Planning a Class III Biosafety Cabinet 3050 mm Dual-Chamber specification?

Отправьте нам ваши габариты, условия монтажа, целевые показатели производительности и требуемую отделку поверхности.

Поговорите с нашей командой
Электронная почта WhatsApp WeChat

Главная

Продукция

Новости

О нас

Контакты