Pembekal Satu Henti Anda untuk Peralatan Bilik Bersih dan Kemudahan AseptikSokongan Projek Antarabangsa
Open mobile navigationClose mobile navigation
Laman Utama / Produk / Containment & Biosafety Equipment / Sterility Test Isolator 2000 mm Four-Glove
STJH-STERILITY-TEST-ISOLATOR-2000-4G

Sterility Test Isolator 2000 mm Four-Glove

The widest standard sterility-test isolator in the retained family, providing four glove positions for high-throughput batch-release work.
  • 2000 mm work chamber
  • Four glove positions
  • Maximum retained airflow capacity
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

A 2000 mm internal work surface and four glove ports provide separate reach zones for larger sample batches. The corresponding 2304 mm external process-chamber envelope and higher documented airflow distinguish this model from the compact and intermediate versions.

Ciri-ciri Utama

High-throughput layout

Four access positions allow samples, test equipment and completed items to occupy distinct sections of the long chamber.

Large process envelope

The increased width supports more extensive staging while preserving a closed aseptic barrier.

Airflow sized to chamber volume

The standard airflow values rise with the chamber size for either total-exhaust or recirculating operation.

Parameter teknikal

Internal Process Chamber2000 x 540 x 700 mm
External Process-Chamber Envelope2304 x 881 x 2430 mm
Glove Ports4
Supply FilterU15, nominal 99.9995% at MPPS
Exhaust FilterH14, nominal 99.995% at MPPS
Total-Exhaust Airflow1703 m³/h
Recirculating Airflow850 m³/h
Work-Zone CapacityFour-position batch testing and staging
Relative Family SizeLargest standard chamber in the retained range
PenyesuaianTransfer capacity, equipment mounting and monitoring can be adapted to the batch-release workload.

Applications

High-volume sterility testing, batch-release microbiology and aseptic quality-control processes requiring four manipulation positions.

Solutions for Your Application

A routine batch exceeds the staging space of a shorter isolator.Allocate the four-glove chamber into inbound, active testing, consumable and completed-sample zones.
The larger chamber increases the facility air requirement.Plan utilities using the published airflow for the chosen total-exhaust or recirculating operating mode.

Pilihan yang boleh didapati

Multiple transfer interfaces, pump and instrument integration, internal organizers and process-monitoring connections may be configured for the batch size.

Planning a Sterility Test Isolator 2000 mm Four-Glove specification?

Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Berbincang dengan pasukan kami
Email Kami WhatsApp WeChat

Laman Utama

Produk

Berita

Tentang Kami

Hubungi Kami