Pembekal Satu Henti Anda untuk Peralatan Bilik Bersih dan Kemudahan AseptikSokongan Projek Antarabangsa
Open mobile navigationClose mobile navigation
Laman Utama / Produk / Peralatan Bilik Bersih / Mobile HEPA Cleanroom Air Purifier 750 CFM
STJH-MOBILE-CLEANROOM-AIR-PURIFIER-750CFM

Mobile HEPA Cleanroom Air Purifier 750 CFM

A low-vibration mobile HEPA unit with 560-750 CFM output and filter-loading indication.
  • 560-750 CFM adjustable duty
  • 50 dBA at 30 in
  • Filter back-pressure gauge
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

Designed for higher portable air-change demand, this self-contained purifier delivers 560 to 750 CFM through a 99.99% HEPA filter. The cabinet combines a 1/4 hp PSC motor, local speed dial and back-pressure gauge, giving operators direct control and a visible maintenance cue. Its cited 50 dBA level at 30 in separates it from the smaller general-purpose mobile unit.

Ciri-ciri Utama

High portable air volume

The upper 750 CFM setting supports faster turnover in rooms that exceed compact purifier capacity.

Maintenance visibility

A filter back-pressure gauge provides a local indication of increasing resistance.

Balanced blower assembly

The forward-curved wheel and permanently lubricated bearings support low-vibration mobile operation.

Parameter teknikal

Airflow Range560-750 CFM
HEPA Efficiency99.99% at 0.3 µm
PrefilterMERV 7
Motor1/4 hp PSC
Power Supply120 V, 60 Hz, single phase
Full-Load Current3.8 A
Reference Sound50 dBA at 30 in
Kawalan Aliran udaraLocal fan-speed dial
Filter MonitoringBack-pressure gauge
PenyesuaianBoleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi.

Applications

Intended for temporary clean zones, healthcare isolation support and laboratory rooms where a portable unit must provide more air changes than a 500 CFM cabinet. Position the unit so gowning traffic cannot block its return path.

Solutions for Your Application

Portable filtration may be too weak for a larger temporary room.Use the adjustable 560-750 CFM range and verify achieved air changes at the selected setting.
Operators may not know when resistance is rising.Track the cabinet pressure gauge and service the prefilter before airflow is materially reduced.

Pilihan yang boleh didapati

Define the operating airflow, discharge direction, cord arrangement and filter-service access. UV-C equipment, if specified, should be managed under the facility maintenance procedure.

Planning a Mobile HEPA Cleanroom Air Purifier 750 CFM specification?

Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Berbincang dengan pasukan kami
Email Kami WhatsApp WeChat

Laman Utama

Produk

Berita

Tentang Kami

Hubungi Kami