Pembekal Satu Henti Anda untuk Peralatan Bilik Bersih dan Kemudahan AseptikSokongan Projek Antarabangsa
Open mobile navigationClose mobile navigation
Laman Utama / Produk / Peralatan Bilik Bersih / FFU Central Control System Dynamic Pressure-Control
STJH-FFU-CENTRAL-CONTROL-DYNAMIC-PRESSURE

FFU Central Control System Dynamic Pressure-Control

An automated room-by-room FFU controller for pressure-cascade and air-change management.
  • Dynamic FFU speed control
  • 5.7 in color touchscreen
  • Pressure and air-change setpoints
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

This third-tier system changes FFU speed dynamically from room pressure and air-change setpoints. A 5.7 in color touchscreen and integrated logging support automated suite operation rather than capacity-only monitoring. It is intended for regulated cleanroom groups where maintaining the pressure cascade is the primary control objective.

Ciri-ciri Utama

Closed-loop room control

Fan speed responds to configured pressure and air-change targets.

Room-by-room strategy

Different zones can be managed around their position in the pressure cascade.

Integrated operating history

Logging supports review of control response and room conditions.

Parameter teknikal

Control ModeDynamic FFU speed control
Display5.7 in color touchscreen
Controlled VariablesRoom pressure and air-change setpoints
Data LoggingIntegrated
Room StrategyRoom-by-room control
Alarm HandlingConfigured system and condition alarms
Fan InterfaceCompatible networked FFU controllers
Operating ModeAutomated pressure-cascade management
InstallationCentral cleanroom control panel
PenyesuaianBoleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi.

Applications

Designed for regulated cleanroom suites with pressure cascades and varying room air-change requirements. Sensors, fan network and control sequence must be commissioned as one system.

Solutions for Your Application

Fixed FFU speeds do not respond to door activity or filter loading.Use dynamic speed control from room pressure and air-change measurements.
Operators cannot see how room setpoints interact.Use the color touchscreen and integrated logs to review each zone.

Pilihan yang boleh didapati

Define room hierarchy, sensors, setpoints, alarm limits, fan addresses and logging needs. Network and sensor compatibility should be confirmed before installation.

Planning a FFU Central Control System Dynamic Pressure-Control specification?

Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Berbincang dengan pasukan kami
Email Kami WhatsApp WeChat

Laman Utama

Produk

Berita

Tentang Kami

Hubungi Kami