Laman Utama / Produk / Cleanroom HVAC Systems / Centrifugal Cleanroom Exhaust-Air Fan Unit 821 CFM
STJH-CENTRIFUGAL-CLEANROOM-EXHAUST-FAN-821CFM

Centrifugal Cleanroom Exhaust-Air Fan Unit 821 CFM

A compact square inline exhaust unit delivering 188-821 CFM with a direct-drive backward-inclined wheel.
  • 188-821 CFM airflow range
  • Direct-drive centrifugal wheel
  • Horizontal or vertical mounting
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

This small centrifugal exhaust unit packages a backward-inclined composite impeller inside a short square casing. Its documented 188-821 CFM range suits local cleanroom extract and return branches, and the inline arrangement can be oriented horizontally or vertically to follow available duct space.

Ciri-ciri Utama

Restricted-space casing

The compact square body can replace a long scroll-fan assembly in a crowded ceiling or service chase.

No belt transmission

Direct drive removes belt tensioning and the associated maintenance access requirement.

Flexible duct orientation

The same inline form supports horizontal or vertical airflow when installed within its mounting limits.

Parameter teknikal

Airflow Range188-821 CFM
Fan ArrangementSquare inline centrifugal
DriveDirect
ImpellerBackward-inclined composite
InstallationHorizontal or vertical inline
CasingCompact square steel enclosure
ConnectionsRectangular duct flanges
AccessRemovable service panel
DutySmall exhaust or return branch
PenyesuaianMotor, controls, coating and duct transitions can be configured for the intended application and operating environment.

Applications

Small cleanroom exhaust branches, gowning-room return air, laboratory support extract and equipment-cabinet ventilation.

Solutions for Your Application

There is insufficient ceiling length for a housed centrifugal fan and transitions.Install the short square inline unit directly between rectangular duct sections.
A belt drive would add particulate-producing wear components above a controlled zone.Use the direct-drive wheel and maintain access to the motor and impeller through the service panel.

Pilihan yang boleh didapati

Speed controller, disconnect, motorized isolation damper, coated casing, flexible connectors and vibration isolation can be supplied.

Planning a Centrifugal Cleanroom Exhaust-Air Fan Unit 821 CFM specification?

Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Berbincang dengan pasukan kami
Email Kami WhatsApp WeChat

Laman Utama

Produk

Berita

Tentang Kami

Hubungi Kami