Pembekal Satu Henti Anda untuk Peralatan Bilik Bersih dan Kemudahan AseptikSokongan Projek Antarabangsa
Open mobile navigationClose mobile navigation
Laman Utama / Produk / Cleanroom HVAC Systems / Air-to-Air Plate Heat Recovery Unit 850 mm
STJH-AIR-TO-AIR-PLATE-HEAT-RECOVERY-850MM

Air-to-Air Plate Heat Recovery Unit 850 mm

A medium crossflow plate core combining greater recovery area with a low-leakage non-silicone seal option.
  • 850 mm plate size
  • 300-1200 mm module width
  • 0.1% leakage option at 400 Pa
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

The 850 mm plate size expands module width to 300-1200 mm and provides more transfer surface than the compact core. Plate spacing from 2.0-6.0 mm supports different pressure and fouling requirements. A non-silicone seal option is documented at maximum leakage of 0.1% at 400 Pa, making this model relevant where low cross leakage and silicone control are important to clean manufacturing.

Ciri-ciri Utama

Medium recovery surface

The larger diagonal increases sensible transfer capacity for commercial clean AHUs.

Low-leakage sealing

A documented non-silicone configuration limits transfer between supply and exhaust streams.

Variable passage geometry

Multiple plate spacings balance pressure drop, cleaning access and exchanger compactness.

Parameter teknikal

Plate Size850 mm
Module Width300-1200 mm
Plate Spacing2.0-6.0 mm options
Plate MaterialAluminum
Maximum Leakage0.1% with non-silicone seal at 400 Pa
Flow ArrangementCrossflow
Moving PartsNone
SealSilicone or non-silicone by selection
Primary DutyMedium low-leakage heat recovery
PenyesuaianBoleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi.

Applications

For medium clean manufacturing and healthcare AHUs requiring separated airstream heat recovery with controlled cross leakage.

Solutions for Your Application

Exhaust contaminants can transfer even through a small core leakage path.Use the low-leakage seal, maintain supply-side pressure bias and verify the stream risk before applying recovery.
The exchanger is selected for efficiency but its pressure loss raises fan energy excessively.Optimize plate spacing and face area using the complete annual energy calculation.

Pilihan yang boleh didapati

Specify flows, recovery target, plate gap, width, seal chemistry, leakage limit, bypass, drain, frost control and casing.

Planning a Air-to-Air Plate Heat Recovery Unit 850 mm specification?

Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Berbincang dengan pasukan kami
Email Kami WhatsApp WeChat

Laman Utama

Produk

Berita

Tentang Kami

Hubungi Kami