STJH-V-BANK-HEPA-H14-305X305

V-Bank HEPA Filter 305 × 305 mm H14

A compact six-pack H14 V-bank that moves 1000 m3/h through a 305 mm square face.
  • 305 mm square face
  • Six V-shaped packs
  • 1000 m3/h nominal flow

Produkteinführung

This compact square element arranges six mini-pleat packs in a 292 mm-deep V-bank. The 305 x 305 mm face carries a nominal 1000 m3/h at 320 Pa while maintaining H14 efficiency of at least 99.995% at MPPS. It is intended for high flow from a restricted opening, where the system has sufficient fan pressure and full-depth filter clearance.

Key Features

High flow per face area

Six banked packs multiply the usable media surface behind a compact square opening.

Small-equipment integration

The 305 mm face suits process tools and narrow AHU sections that cannot accept a full module.

Defined fan requirement

A 320 Pa initial drop gives designers a clear starting point for available-pressure checks.

Technische Parameter

External Dimensions305 x 305 x 292 mm
HEPA RatingH14 / at least 99.995% at MPPS
Nominal Volume Flow1000 m3/h
Initial Pressure Drop320 Pa
MediaHigh-efficiency microglass
Internal LayoutSix V-shaped mini-pleat packs
Humidity ResistanceSuitable for up to 100% relative humidity
Installation DepthFull 292 mm box depth required
Selection UseHigh flow through restricted face area
CustomisierungVerfügbar je nach beabsichtigter Anwendung und Betriebsumgebung.

Applications

Used in compact process tools, small clean-air recirculation sections and restricted-face final-filter housings requiring 1000 m3/h. It is not a low-pressure panel substitute: the fan and casing must be evaluated for the 320 Pa clean condition and subsequent loading.

Solutions for Your Application

The available filter opening is small but the equipment needs substantial airflow.Six V-shaped packs place enough media behind a 305 mm square face for a nominal 1000 m3/h duty.
A compact fan cannot overcome the filter resistance after installation.Reserve at least the documented 320 Pa clean-filter allowance plus the selected loading margin in the fan calculation.

Verfügbare Optionen

Confirm airflow direction, casing seal, handling grips, available fan pressure and service-clearance depth before selecting the compact V-bank.

Planning a V-Bank HEPA Filter 305 × 305 mm H14 specification?

Senden Sie uns Ihre Abmessungen, Installationsbedingungen, Leistungsziele und gewünschte Oberflächenveredelung.

Sprechen Sie mit unserem Team